(Function mode 1)
Display
Function
sequence
No.
6
F-05
Motor
constant
7
F-06
Accelera- tion time
tion time
8
F-07
Decelera- tion time
tion time
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
(Function mode 2)
Function
Initialization display
name
contents
Motor
AUX M
123.60 mH
M setting
constant
Motor
AUX J
0.44 kgm
J setting
constant
Motor
AUX Kp
constant
Kp setting
Motor
AUX Ti
constant
Ti setting
Motor
AUX KPP
constant
KPP setting
Accelera-
ACC 1
setting
2-stage
ACC 2
acceleration
time setting
Curve
ACC LINE
pattern
selection
for
acceleration
Accelera-
ACC GAIN
tion and
deceleration
curve
constant
selection
Decelera-
DEC 1
setting
2-stage
DEC 2
deceleration
time setting
Curve
DEC LINE
pattern
selection
for
deceleration
Accelera-
DEC GAIN
tion and
deceleration
curve
constant
selection
Initialization
Rated capacity
of each inverter
2
Rated capacity
of each inverter
002.00
2.0
00100 ms
100 ms
001.00
1.0
0030.00 s
30.00 s
0015.00 s
15.00 s
L
L
02
2 (common to
acceleration
and
deceleration)
0030.00 s
30.00 s
0015.00 s
15.00 s
L
L
02
2 (common to
acceleration
and decelera-
tion)
12-6
Setting, change
Setting contents
contents
0 to 655.35
• Primary self inductance per
phase.
0 to 655.35
• Motor and machine inertia
0 to 100.00
• Smaller: High response
• Larger: Low response
0 to 10000
• Set this item after the
feedback option PCB is
installed.
0 to 100.00
• Set this item after the
feedback option PCB is
installed.
0.01 to 3000
• When the fuzzy most
suitable acceleration and
deceleration (F-10) are set,
the time displayed here is
invalid, though it can be
set.
0.01 to 3000
• The acceleration time can
be used when the input
terminal CH1 is shorted.
• For input terminal
selection, refer to F-34
input terminal.
L (Linear),
• The curve pattern is set for
S (S curve),
acceleration and
U (U curve),
deceleration respectively.
RU (reverse
U curve)
1 to 10
• When the constant is set
for one of acceleration and
deceleration, it is common
to both acceleration and
deceleration.
• See appendix 4.
0.01 to 3000S
• When the fuzzy most
suitable acceleration and
deceleration (F-10) are set,
the time displayed here is
invalid, though it can be
set.
0.01 to 3000S
• The deceleration time can
be used when the input
terminal CH1 is shorted.
• For input terminal
selection, refer to F-34
input terminal.
L (Linear),
• The curve pattern is set for
S (S curve),
acceleration and decelera-
U (U curve),
tion respectively.
RU (reverse
U curve)
1 to 10
• When the constant is set
for one of acceleration and
deceleration, it is common
to both acceleration and
deceleration.
• See appendix 4.