Utilities – GFCI Test Feature
Not Available on CE Rated Systems.
A GFCI is an important safety device and is required equipment on a hot tub installation.
Your spa may be equipped with a GFCI Protection feature. (UL rated systems only.) If your spa has this feature enabled by
the manufacturer, the GFCI Trip Test must occur to allow proper spa function.
Within 1 to 7 days after startup, the spa will trip the GFCI to test it. (The number of days is factory programmed.) The GFCI
must be reset once it has tripped. After passing the GFCI Trip Test, any subsequent GFCI trips will indicate a ground fault or
other unsafe condition and the power to the spa must be shut off until a service person can correct the problem.
Main Screen
To FIRST item in
Main Menu
(TEMP Range)
Only if GFCI
is enabled
To next item in
Info Menu
(A/B°)

Forcing the GFCI Trip Test

The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu.
The GFCI should trip within several seconds and the spa should shut down. If it does not, shut down the power and manu-
ally verify that a GFCI breaker is installed and that the circuit and spa are wired correctly. Verify the function of the GFCI
with its own test button. Restore power to the spa and repeat the GFCI Trip Test.
Once the GFCI is tripped by the test, reset the GFCI and the spa will operate normally from that point. You can verify a suc-
cessful test by navigating to the above menu. PASS should appear after a temp button is pressed from the GFCI screen.
The end-user must be trained to expect this one-time test to occur and how to properly reset the GFCI.
Warning:
If freezing conditions exist, a GFCI should be reset immediately or spa damage
could result. The end user should always trained to test and reset the
GFCI on a regular basis.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
40940_G
While the Temperature is
still flashing, press Light
repeatedly until UTIL (Utilities)
appears in the LCD.
One of these screens
will appear.
Only appears
if a GFCI test
has been
passed.
Waiting several seconds inside the GFCI Menu will allow the screen to return to normal operation.
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message - every 1/2 second
A temperature button, used for "Action"
Light or dedicated "Choose" button, depending on control panel configuration
Waiting time - varies depending on function
When the GFCI trips,
the spa will shut down.
After the breaker is
TRIP may also
reset, PASS will
appear briefly
appear in this menu
under certain
and the spa will
circumstances.
operate normally.
If the GFCI does
The GFCI will be tripped
NOT trip, FAIL will
at a random interval.
appear and Spa
will not operate.
Indicates a Menu Item that
Depends on a Manufacturer
Configuration and
may or may not appear.
12-12-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents