TROUBLESHOOTING YOUR SPA

COMMON PROBLEMS AND HOW TO SOLVE THEM
A large number of problems on start up can be attributed to mis-wiring and
a poor understanding of how the spa operates and its' features. Take the
time to read and understand this manual. If you have any questions contact your dealer.
GROUND FAULT CIRCUIT INTERRUPTER (GFCI) OR RESIDUAL CURRENT
DETECTOR (RCD) SHUTS OFF ON INITIAL START UP
Probable
Mis-wiring of GFCI/RCD.
cause:
Action:
Contact electrician and/or dealer.
GROUND FAULT CIRCUIT INTERRUPTER (GFCI) or RESIDUAL CURRENT
DETECTOR (RCD) SHUTS OFF (NOT ON INITIAL START UP)
Probable
One or more pieces of equipment is shorting to ground or total current draw exceeds
cause:
GFCI/RCD rating.
Action:
Contact dealer: DO NOT use spa. Take measures to ensure others do not use spa.
SPA IS COMPLETELY "DEAD" (NO CIRCULATION AND NO DISPLAY ON TOPSIDE
CONTROL PANEL)
Probable
GFCI/RCD has tripped (shut off).
cause #1:
Action:
Reset GFCI/RCD and monitor for futures trips. Alert dealer if problem persists.
Probable
Breaker or fuse before GFCI/RCD is tripped or blown.
cause #2:
Action:
Shut off GFCI/RCD, reset breaker or replace fuse, reset GFCI/RCD and test. Contact
electrician or dealer if problem persists.
Probable
Transformer fuse blown in spa pack.
cause #3:
Action:
Locate fuse in spa pack, test and/or replace. Or contact dealer for service.
Probable
Insufficient line voltage to power up spa pack processor.
cause #4:
Action:
Contact electrician to measure line voltages and inspect supply connections.