Note: In new installations, GFCI trippings due to mis-wiring are very common.
If the breaker is properly wired, GFCI trippings can occur when the total amount of current drawn by the
spa exceeds the rating of the breaker. Such an occurrence, however, is very unlikely, since each output of
the spa pack is individually fused and fuses will blow before the GFCI trips. A current leak to the ground
will also make the GFCI trip. If one or more of the components is faulty and there is a leak of more than 5
mA, the GFCI will trip to prevent electrocution.

230 VOLT SUPPLY CONNECTION

Power Up Screen
Each time the system powers up, a series of numbers is displayed. After the start-up sequence of
numbers, the system will enter Priming Mode. Next, refer to the User Guide for your keypad at the back of
this manual.

NORTH AMERICAN (60HZ) MODELS

Please note the following important information:
When using this electrical equipment, basic safety instructions should be followed, including the following:
READ AND FOLLOW ALL DIRECTIONS
1) Electrical installation must be carried out by a qualified electrician strictly in accordance with local
governing codes.
2) A terminal marked "ground" is located within the control box. To reduce the risk of electric shock
this terminal must be connected to the grounding means provided in the electric supply service
panel with a continuous copper wire equivalent in size to the circuit conductors supplying the
equipment.
3) At least two lugs marked "bonding lugs" are provided on the external surface of the control box. To
reduce the risk of electric shock connect the local common bonding grid in the area of the hot tub
or spa to these terminals with an insulated or bare copper conductor not smaller than No. 6 AWG.
4) All field installed metal components such as rails, ladders, drains or other similar hardware within
3m (10 ft.) of the spa or hot tub shall be bonded to the equipment grounding bus with copper
conductors not smaller than No. 6 AWG.
5) Test the ground fault circuit interrupter before each use of the spa.
6) Before servicing any electrical components of the system make sure that the power supply is
switched off.
Sunrise Spas 2014 Owner's Manual

Power Requirements

240VAC, 60Hz, Class A GFCI-protected service
4 wires (Hot-Line 1, Hot-Line 2, Neutral, Ground)
For current requirements & breaker rating see nameplate on spa.