Wolf cinema REF-700 Owner's Manual page 69

Home theater projectors
Table of Contents

Advertisement

Read through the entire procedure before attempting to adjust White Field Uniformity controls, and keep in mind 
the following checklist of prerequisites and guidelines: 
 
ADJUST COLORS FIRST — Always adjust the primary colors as described in the "Matching Colors in 
Multiple Screens" procedure (above) before attempting to work with White Field Uniformity. This insures 
that primary colors, color temperature, and maximized light output are all well matched from one screen 
to another. These matches are needed before you can achieve good White Field Uniformity results. 
 
RUN LAMP FOR 100 HOURS— Light output and White Field Uniformity can vary significantly during the 
first 100 hours of lamp use. For best results with new lamps, either set up White Field Uniformity after 
this period, or do an initial setup and re‐check at 100 hours 
 
SET LAMP POWER — Insure that each "Lamp Power" setting is as high as possible for your application 
while still maintaining a good overall match of light output from screen to screen. By nature, achieving a 
uniform brightness will require a slightly reduced overall brightness—this reduction will help insure that 
you have enough range of adjustment when examining brightness variables more closely from screen‐to‐
screen, and will help prevent premature "maxing out" when trying to match to a certain color, zone or 
projector. 
 
USE A "USER" COLOR TEMPERATURE — Always adjust White Field Uniformity for a User color 
temperature defined when you matched primary colors, and continue to use it for all sources displayed 
on the wall. Your other color temperatures will not necessarily be matched from screen‐to‐screen. 
 
WHITE UNIFORMITY SLIDE BARS — White Uniformity slide bar values may not reduce to "0". Each slide 
bar adjusts overall light output in a specific screen zone, but the value shown represents the current 
setting for green in this zone. When other "hidden" values (red or blue) are lower than green, during 
adjustment in the White Uniformity menu their values will reach "0" first, causing the slide bar to stop 
earlier than expected. 
 
JUDGE BY EYE OR USE A METER — Good White Field Uniformity can be achieved with either. 
 
Step 1: General Setup 
 
1a)  Adjust primary colors (see Matching Colors in Multiple Screens) to insure matched overall color temperatures 
and light output between screens. 
IMPORTANT:  Double‐check that all WHITES and LIGHT OUTPUT are well‐matched. 
 
1b) Enable the White Field Uniformity checkbox. This will enable 
access to the uniformity controls and will apply the settings to your 
image. 
 
1c) Select the 13‐Point test pattern for display. This pattern provides 
nine screen "zones" with 13 targets.   
 
 