OSD - SYSTEM - CONTROL
CONTROL
Use arrow keys to navigate in the SYSTEM menu to the entry CONTROL and press ENTER/SELECT to open
the CONTROL window.
NTI devices can be controlled via DCP (Device Control Protocol), an XML-based protocol.
(see page 71 in Annex)
There are two DCP modes:
DCP control,
DCP synchronize,
Default setting is "off",
Use a serial cable to connect a control unit to the RS 232 port (RJ 45) on the SPLITMUX-DVI-4 rear panel.
To synchronize several devices, special Y cables are required.
Settings for the connection are:
Transfer rate 57600 baud, 8 data bits, no parity, 1 stop bit, no flow control
The two control modes operate as follows:
DCP control
This mode allows direct control of a single switch
by means of a control device, e.g. a computer.
The control device can query and change the
mode of SPLITMUX-DVI-4.
SPLITMUX-DVI-4 responds to each DCP message
sent by the control device with a DCP reply.
This reply includes the values of all settings queried
or set by means of the last message. If the message
sent by the control unit contains errors, the switch
will reply by sending an error message.
SPLITMUX-DVI-4 - Installation and Operation Manual
which allows external control of the display mode.
which keeps several SPLITMUX-DVI-4 devices in the same display mode.
which prevents any external CONTROL.