1.
Install foam gasket.
INSTALL FOAM GASKET
2.
Attach flue adaptor to back of heater with four (4) screws.
3.
Install plastic gasket and screw threaded connector to the flue adaptor.
When these connections are made, continue with your vent run. Cement
all PVC joints on vent run.
25700-1-0809
Available from Empire Comfort Systems, Inc.
Figure 25
Figure 26
PLASTIC GASKET
THREADED CONNECTOR
Figure 27
FLUE ADAPTOR
Note: No PVC cement is needed
8-8 x 1/2" Phillips Truss Head Screw
to install flue adaptor kit.