Vent System Identification - Horizontal - Empire Comfort Systems DVLXG75BP90N-1 Installer's Manual

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

Begin the vent system installation by selecting the type of venting
to be installed and the path it will take. Verify clearances are met
throughout the path of the venting system.
Determine how the vent system will be terminated out the
side of the house or through the roof. Verify clearances for the
termination.
When selecting a vent system for use with the fireplace, refer
to the Empire Comfort Systems Retail Price List for Simpson
Duravent part numbers and pricing. Check all clearances and
venting components. Identify if any problems exist in the vent
system.
Check pipe diameter on vent system and fireplace to verify the
size is the same.
NOTICE: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.

VENT SYSTEM IDENTIFICATION - HORIZONTAL

Wall Strap
90
Elbow
o
90
or 45
Elbow
o
o
Pipe Length
Ceiling Fire Stop
Wall Strap
90
Elbow
o
NOTICE: Additional pipe may be required for proper venting
Wall Thimble
Horizontal Termination
(Maximum Six 90
Elbows)
o
35