Empire Comfort Systems DVX36DP31(N,P)-1 Installation Instructions And Owner's Manual

Studio series direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

Quick Links

The Studio Series Direct Vent Zero
Clearance Gas Fireplace Heater
Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
UL FILE NO. MH30033
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by state or local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel or
from fuel combustion which can cause death or seri-
ous illness.
AND
LUXURY DIRECT VENT
GAS FIREPLACE HEATER
MODEL SERIES
MILLIVOLT STANDING PILOT
DVX36DP31(N,P)-1
DVX42DP31(N,P)-1
INTERMITTENT PILOT
DVX36DP71(N,P)-1
DVX42DP71(N,P)-1
REMOTE RF
DVX36DP91(N,P)-1
DVX42DP91(N,P)-1
GAS-FIRED
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire Comfort Systems DVX36DP31(N,P)-1

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS OWNER’S MANUAL The Studio Series Direct Vent Zero LUXURY DIRECT VENT Clearance Gas Fireplace Heater GAS FIREPLACE HEATER MODEL SERIES MILLIVOLT STANDING PILOT DVX36DP31(N,P)-1 DVX42DP31(N,P)-1 INTERMITTENT PILOT DVX36DP71(N,P)-1 DVX42DP71(N,P)-1 REMOTE RF DVX36DP91(N,P)-1 DVX42DP91(N,P)-1 GAS-FIRED Installer: Leave this manual with the appli- ance.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Section Page Important Safety Information .............................3 Safety Information for Users of LP Gas ........................4 Requirements for Massachusetts ..........................5 Introduction .................................6 Specification................................7 Fireplace Dimensions ..............................7 Clearances ...................................8 Locating Fireplace ..............................8 Gas Supply ..................................9 Installation ................................10-13 Venting Fireplace - Top ............................14-17 Examples - Top Vent Run ............................18 DVVK-4FV Direct Vent Termination Kit ......................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED • If this appliance is installed directly on carpeting, tile • Adequate accessibility clearances for servicing and proper or other combustible material other than wood flooring operation.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone’s safety will depend colorless.
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed 3. SIGNAGE. A metal or plastic identification plate shall be in every dwelling, building or structure used in whole or in part permanently mounted to the exterior of the building at a for residential purposes, including those owned or operated by the minimum height of eight (8) feet above grade directly in line Commonwealth and where the side wall exhaust vent termination...
  • Page 6: Introduction

    (a) the installation or replacement of gas piping or (b) the • Modification of the fireplace or direct vent system. connection, installation, repair or servicing of equipment, who is • Installation other than as instructed by Empire Comfort Systems, experienced in such work, familiar with all precautions required Inc.
  • Page 7: Specification

    SPECIFICATIONS DVX36 NAT DVX36 LP DVX42 NAT DVX42 LP Input Btu/hr Maximum 35,000 30,000 37,500 35,000 Btu/hr Minimum 24,000 21,000 26,000 24,000 KWH (Maximum) 10.3 11.0 10.3 (Minimum) Orifice #32 (P-211) 1.65 mm (P-250) #31 (P-209) #50 (P-245) Air Shutter Opening 1/4"(6.4 mm) FULL OPEN 1/4"...
  • Page 8: Clearances

    CLEARANCES Mantel Chart (Figure 3) Clearance to Combustibles Back 0" (0 mm) 12” (305mm) Side 0" (0 mm) 10” (254mm) Floor 0" (0 mm) MANTEL Top Stand-off 0" (0 mm) Top Framing Edge 6" (152 mm) COMBUSTIBLE TRIM AND 8” MANTELS ALLOWED IN SHADED AREA 6”...
  • Page 9: Gas Supply

    GAS SUPPLY Installing a New Main Gas Cock The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Each appliance should have its own manual gas cock. Z223.1 CAN/CGA-B149 (.1 or .2) installation code.
  • Page 10: Installation

    INSTALLATION Framing and Finishing VENT PIPE Choose unit location. Frame in fireplace with a header across the top. It is important to allow for finished face when setting the depth of the frame. Attach fireplace to frame using adjustable nailing flange. Preset depth to suit facing material (adjustable to 3/8", 1/2"...
  • Page 11 INSTALLATION (continued) DVX36 DVX42 "A" 40 7/8" 40 7/8" NAIL OR OTHER SUITABLE FASTENER "B" 40 3/8" 43 3/8" Figure 10 "C" 19 7/8" 19 7/8" Framing (Figure 11) Figure 11 Fireplace framing can be built before or after the fireplace is set in place.
  • Page 12 Flush Wall Installation Attention: Cold climate installation recommendation: FINISHED WALL When installing this unit against a non-insulated exterior 6” OF NON-COMBUSTIBLE MATERIAL wall, it is recommended that the outer walls be insulated to NON-COMBUSTIBLE MATERIAL conform to applicable insulation codes. (INSTALLATION IS OPTIONAL Vent Runs (Figures 14, 15, and 16) In planning the installation for the fireplace, it is necessary to install...
  • Page 13: Installation

    INSTALLATION (continued) VERTICAL, 90° ELBOW TO CORNER INSTALLATION VERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALL HORIZONTAL OUT THE WALL “A” WALL FIRESTOP/ 90º ELBOW “A” THIMBLE PIPE LENGTH “B” 6” (152mm) MINIMUM “C” VENT 9” (229mm) “D” MINIMUM VENT CAP WALL FIRESTOP/ THIMBLE “C”...
  • Page 14: Venting Fireplace - Top

    VENTING FIREPLACE - TOP Venting Graph (Dimensions in Feet) To Use the Vent Graph (Figure 17) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, TOP EXIT - VERTICAL AND HORIZONTAL TERMINATION (DIMENSIONS IN FEET) locate the point it intersects with the slanted graph line.
  • Page 15 VENTING FIREPLACE - TOP (continued) Installation of Flue Heat Shield HOLES FOR 42” MODELS Remove flue insulation. Remove (2) screws on outside of inlet vent adapter. See Figure 18. Lift top shield placing flue heat shield around flue. Replace (2) screws on outside of inlet vent adapter. See Figure 19.
  • Page 16 VENTING FIREPLACE - TOP (continued) Below Grade Installation When it is not possible to meet the required vent terminal clearances of 12" (305mm) above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178 mm) below grade level. The 7"...
  • Page 17 10” (254mm) VENT CAP 12” (305mm) SEE CHART FOR PERMISSIBLE “H” AND “V” DIMENSIONS 9” (229mm) minimum TO SIDE WALL CENTER OF ELBOW STRAIGHT OUT (MINIMUM) Figure 24 3’ (914mm) Figure 23 MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE FIREPLACE HARD ELBOW DIMENSIONS...
  • Page 18: Examples - Top Vent Run

    EXAMPLES - TOP VENT RUN Example H2 3ft, H3 1ft = 4ft (90° + 90° + 90°) = 6ft V1 = 21ft H = 10ft V = 21ft Figure 27 Figure 26 Example H1 = 2ft V1 = 20ft H = 2ft V = 20ft Figure 28 Page 18...
  • Page 19: Dvvk-4Fv Direct Vent Termination Kit

    DVVK-4FV DIRECT VENT TERMINATION KIT Installation Instructions This termination kit can only be used with Empire Comfort Systems direct vent fireplaces listed for use with DVVK-4FV Vertical Flex Vent Kit. Please review the instructions packaged with your fireplace and verify the fireplace model number.
  • Page 20 DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) PRE-INSTALLATION INFORMATION: Items Required For Installation: Tools Building Supplies Phillips Screwdriver Framing Materials Hammer Wall Finishing Materials Saw and/or saber saw Caulking Material (Noncombustible) Level Support Strap supplies Measuring Tape Electric Drill and Bits Pliers Square Tin Snips...
  • Page 21 DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) Step-By-Step Installation For Flex DV Kit Unpack vent components and check all items for shipping 5. Next, determine the location for the cutout in the roof open- damage. ing. This opening must be large enough to provide a mini- For this venting system to operate as designed it is depen- mum 1”...
  • Page 22 DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) 10. With the flex vent assembly and the 48” long hard pipe com- 13. Now the pre-assembled vent system may be carried to the ponents laid out on the floor, begin securing these parts to- roof, then lowered through the roof cutout opening (see step gether.
  • Page 23 DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) 17. To attach the vent connections at the fireplace, be sure the 7” 21. An additional storm collar band is provided in kit that may be diameter adapter collar has been installed per step 3. Apply used as an attic insulation shield.
  • Page 24 DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) VERTICAL TERMINATION STORM COLLAR 4’ LONG RIGID PIPE ROOF FLASHING ADJUSTABLE ROOF JACK ASSEMBLY ROOF EXTERIOR CLEARANCE TO COMBUSTIBLES REQUIRED FROM VENT PIPE CLAMPS AT FLUE & INLET VENT CONNECTIONS ADJUSTABLE STORM COLLAR (USE TO FIRESTOP/THIMBLE KEEP INSULATION OUT OF ASSEMBLY...
  • Page 25: Dvvk-4Fv Direct Vent Termination Kit

    DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) Vertical Flex Termination Kit Item Quantity Number Item Description Repair Part No. Supplied 4”/7” Vertical Termination Cap MF100038 Roof Support Kit MF100503 2 Ply Alum Flex 4” Diameter by 6 ft. MF04ALA2F006 2 Ply Alum Flex 7” Diameter by 6 ft. MF07ALA2F006 4”/7”...
  • Page 26: Dvvk-4Re Vent Kit Installation Instructions

    DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS CAUTION: Sharp edges, use protective gloves when NOTE: SPACING FLANGE installing. INSTALLED TO TOPSIDE Tools Needed for Installation: Sheet metal snips 5/16” nut driver Phillips head screwdriver - #2 High temperature sealant or furnace cement rated for continuous use at 1,000 F minimum 11”...
  • Page 27 DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) 7. Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8” (168 mm) diameter VINYL SIDING KIT DV822 tube from the opposite end. Do not crimp or enlarge tube. OUTSIDE MOUNTING 8.
  • Page 28: Dvvk-4Re Vent Kit Installation Instructions

    DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) Follow correct option according to venting method. Connecting to Rigid Vent System If the air inlet and flue outlet tubes are to be connected to a rigid Connecting Directly to Fireplace venting system (and not directly to the back of the unit), then do If the air inlet and flue outlet tubes are to be connected directly to not use the gasket provided.
  • Page 29: Dvvk-4F Flex Vent Instructions

    DVVK-4F FLEX VENT INSTRUCTIONS The DVVK-4F FLEX VENT KIT includes the following components: • (1) Horizontal Termination Cap • (1) 7" diameter Outer Vent adapter collar • (1) 4-foot section of Flex vent with spacers (4" flue/7" outer • (1) Wall Firestop/Thimble Assembly pipe) •...
  • Page 30: Termination Clearances

    TERMINATION CLEARANCES Termination clearance for buildings with combustible and noncombustible exteriors. INSIDE CORNER OUTSIDE CORNER RECESSED LOCATION “A” = COMBUSTIBLE 9” (229mm) “F” = COMBUSTIBLE 6” (152mm) = NONCOMBUSTIBLE 2” (51mm) = NONCOMBUSTIBLE 6” (152mm) BALCONY BALCONY WITH PERPENDICULAR SIDE WALL WITH NO SIDE WALL “C”...
  • Page 31: Vent Clearances

    VENT CLEARANCES AREA WHERE TERMINAL IS NOT PERMITTED VENT TERMINAL AIR SUPPLY INLET Figure 47 *Clearance above grade, veranda, porch, deck or balcony clearance to non-mechanical air supply inlet to building or [*12 inches (30cm) minimum] the combustion air inlet to any other appliance [*12 inches (30cm) minimum for appliances ≤...
  • Page 32: Vent System Identification

    VENT SYSTEM IDENTIFICATION Special Venting Components (Simpson Duravent) See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers and pricing. Special DV Vent Kits Special DV Vent Kits Available from Empire Comfort Systems, Inc. dealers. Available from Empire Comfort Systems, Inc. dealers.
  • Page 33: Framing And Finishing

    FRAMING AND FINISHING Installing Support Brackets (Figure 49) A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports should be placed around the pipe and nailed in place to framing members. There MUST BE a 3 inch clearance to combustibles above flue pipe and elbows and 1 inch clearance on both sides and bottom of the flue pipe to combustibles on all horizontal pipe sections and elbows.
  • Page 34: Framing And Finishing

    FRAMING AND FINISHING (continued) EXISTING CEILING JOISTS NAILS, 4 REQUIRED CEILING FIRESTOP NEW FRAMING CEILING BELOW Vent Size Vent Size 6 5/8" 10" 10" 6 5/8" 10" 10" 8" 10 1/2" 10 1/2" 8" 10 1/2" 10 1/2" Figure 51 Figure 53 See Horizontal Termination Page 35 and Vertical Termination Pages 37 and 38.
  • Page 35: Horizontal Termination

    HORIZONTAL TERMINATION NOTE: Termination cap should pass through the wall firestop from the exterior of the building. Adjust the termination cap to its final exterior position on the building. Warning: Termination cap must be positioned so that arrow is pointing up. CUT VINYL SIDING AWAY Attach the termination cap with the four wood screws provided.
  • Page 36: Dvvk-5F Flex Vent Instructions

    DVVK-5F FLEX VENT INSTRUCTIONS The DVVK-5F FLEX VENT KIT includes the following components: • (1) Horizontal Termination Cap • (1) Wall Firestop/Thimble Assembly • (1) 4-foot section of Flex vent with spacers (5" flue/8" • Hardware pack that includes band clamps and screws outer pipe) with flue adapter collar Flex venting can only be installed vertically off of the DVX Series fireplaces.
  • Page 37: Vertical Termination

    VERTICAL TERMINATION Locate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive this nail through this center point. Make the outline of the roof hole around this center point. NOTE: Size of the roof hole dimensions depend on the pitch of the roof.
  • Page 38 All damaged gaskets on the glass frame assembly and combustion chamber must be replaced by a qualified service person. If damage occurs to the combustion chamber, it must be replaced by a qualified service person. Contact Empire Comfort Systems, Inc. for replacement parts. Page 38...
  • Page 39: Log Identification

    LOG IDENTIFICATION REAR BOTTOM LOG (A) REAR TOP LOG (B) Part Number - R9228 Part Number - R9222 BOTTOM LEFT LOG (C) BOTTOM LEFT CENTER LOG (D) Part Number - R9227 Part Number - R9372 BOTTOM RIGHT CENTER LOG (E) BOTTOM RIGHT LOG (F) Part Number - R9225 Part Number - R9229...
  • Page 40: Log Placement (13 Log Set)

    LOG PLACEMENT (13 LOG SET) 6. Place Bottom Left Log (C) on far left pin of burner. The "lip" Before you begin: If you are installing logs into the DVX36 or of the log will hang off the side of the burner. DVX42 model then this fireplace is supplied with a set of 13 ceramic fiber logs.
  • Page 41 LOG PLACEMENT (13 LOG SET) Place Bottom Right Log (F) on far right pin on the burner. The 12. Place Top Left Log (I) on two left pins on (B) Log. "lip" of the log will hang off the side of the burner. 13.
  • Page 42 LOG PLACEMENT (13 LOG SET) 15. Place Front Center Log (L) between third and fourth grates on 18. Replace glass door onto firebox. the burner. The short "Y" branch will point left and the bottom 19. Secure the two glass frame spring clamps at bottom of of the "Y"...
  • Page 43 LOG PLACEMENT (13 LOG SET) Figure 65 Figure 66 Log Set Parts List Index Letter Part Number Description R9228 Rear Bottom Log R9222 Rear Top Log R9227 Bottom Left Log R9372 Bottom Left Center Log R9225 Bottom Right Center Log R9229 Bottom Right Log R9223...
  • Page 44: Operating Instructions

    OPERATING INSTRUCTIONS 750 Millivolt System The OWNER should carefully read and follow these operating The standing pilot (750 millivolt system) is a continuous burning instructions at all times. Lower the door assembly to view the gas pilot. The pilot remains ON even when the main burner is OFF. controls for the fireplace.
  • Page 45: Operating Instructions

    OPERATING INSTRUCTIONS (continued) STANDING PILOT OPERATING INSTRUCTIONS Installation of Remote Receiver Remote/Off/On Switch Place remote receiver on the floor of fireplace behind the louver The fireplace is equipped with a Remote/OFF/ON switch. A wire as far forward as possible. harness is attached to the Remote/OFF/ON switch. The red, black Attention: The velcro loop and hook are not necessary in this and green (wires) female push-ons attach to the Remote/OFF/ installation but can be used to secure remote receiver.
  • Page 46: Standing Pilot Wiring Diagram

    STANDING PILOT WIRING DIAGRAM REMOTE CONTROL RECEIVER (OPTIONAL) THERMOSTAT (OPTIONAL) WALL SWITCH GAS VALVE REMOTE/OFF/ON SWITCH (OPTIONAL) REMOTE CONTROL RECEIVER REMOTE/OFF/ON SWITCH GREEN REMOTE BLACK GREEN THERMOPILE IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH NO.
  • Page 47: Standing Pilot Lighting Instructions

    STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. •...
  • Page 48: Standing Pilot Troubleshooting

    STANDING PILOT TROUBLESHOOTING With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
  • Page 49: Intermittent Pilot Operating Instructions

    INTERMITTENT PILOT OPERATING INSTRUCTIONS The intermittent pilot (120/24 volt system) is ON when the main Provided on the intermittent pilot wiring harness are two (2) stripped and bare wires that are labeled THERMOSTAT. The wires will be burner is ON. When the main burner is OFF the intermittent pilot used for attachment of 24 volt thermostat, optional FWS-1 wall is OFF.
  • Page 50: Intermittent Pilot Lighting Instructions

    INTERMITTENT PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device •...
  • Page 51: Intermittent Pilot Troubleshooting

    A. Turn the thermostat to its lowest setting. B. Wait one minute. The Service Department at Empire Comfort Systems, Inc. may be As you do Steps 4 and 5, watch for points where operation contacted to assist in servicing furnace.
  • Page 52 INTERMITTENT PILOT TROUBLESHOOTING (continued) spark generator and energizes the second main valve operator. The Safety Lockout second main valve opens and gas flows to the main burner, where S8600H provides 100 percent shutoff, or safety lockout. A timer it is ignited by the pilot burner. The flame current also holds the starts timing the moment the trial for ignition starts.
  • Page 53 INTERMITTENT PILOT TROUBLESHOOTING (continued) Important WARNING 1. The following service procedures are provided as a general When performing the following steps, do not touch stripped guide. end of jumper or SPARK terminal. The ignition circuit 2. Meter readings between gas control and ignition module must generates 13,000 volts at 25 pf load and electrical shock be taken within the trial for ignition period.
  • Page 54 INTERMITTENT PILOT TROUBLESHOOTING (continued) Page 54 25613-0-0309...
  • Page 55 INTERMITTENT PILOT TROUBLESHOOTING (continued) Green LED Status Codes Green LED Flash Code (X + Y) Indicates Next System Action Recommended Service Action No “Call for Heat” Not applicable None Flash Fast Startup-Flame sense calibration Not applicable None Heart Beat Normal operation Not applicable None Recycle...
  • Page 56: Rf Standing Pilot Operating Instructions

    RF STANDING PILOT OPERATING INSTRUCTIONS Features Benefits • Self powered millivolt receiver/valve • No external power or batteries required to operate valve and flame modulation • Thermostat performance • Flame cycles and modulates such that heat output equals heat loss from the room •...
  • Page 57: Rf Transmitter Functions

    RF TRANSMITTER FUNCTIONS FIRST USE OF TRANSMITTER Status Action Begin communication between transmitter and receiver/valve. Move LOCAL/REMOTE Switch to LOCAL position for at least two seconds; then move switch to the REMOTE position. Transmit unique code. Press Fan or Flame key within 30 seconds. Confirm recognition between transmitter and receiver/valve.
  • Page 58: Rf Wiring Diagram

    RF WIRING DIAGRAM WIRING DIAGRAM WITH BLOWER Figure 72 Page 58 25613-0-0309...
  • Page 59: Rf Standing Pilot Lighting Instructions

    RF STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted by C.
  • Page 60: Maintenance And Service

    MAINTENANCE AND SERVICE Glass Cleaning Please Note It will be necessary to clean the glass periodically. During start-up It is normal for appliances fabricated of steel to give off condensation, which is normal, forms on the inside of the glass and some expansion and/or contraction noise during the start causes lint, dust and other airborne particles to cling to the glass up or cool down cycle.
  • Page 61: Maintenance And Service

    MAINTENANCE AND SERVICE Glass Removal and Replacement (Figures 73 and 74) Remove decorative front doors (where applicable) by opening and lifting straight up. Remove decorative front by tilting lower portion forward to release ball catch and lifting front off mounting bracket. See Figure 73.
  • Page 62: Parts View

    PARTS VIEW BLOWER ASSEMBLY MILLIVOLT VALVE ASSEMBLY RF VALVE ASSEMBLY IP VALVE ASSEMBLY Note: Refer to page 43 when ordering logs. Page 62 25613-0-0309...
  • Page 63: Parts List

    PARTS LIST DVX36DP(31,71,91) Part Number Index No. Description DVX36DP31 DVX36DP71 DVX36DP91 DVX42DP31 DVX42DP71 DVX42DP91 R9347 R9347 R9347 R9348 R9348 R9348 Insulation, Top Shield 26069 26069 26069 26069 26069 26069 Top Shield 23219 23219 23219 23219 23219 23219 Top Standoff (Qty. 2) R7566 R7566 R7566...
  • Page 64: Parts List

    PARTS LIST DVX42DP(31,71,91) Part Number Index No. Description DVX36DP31 DVX36DP71 DVX36DP91 DVX42DP31 DVX42DP71 DVX42DP91 P250 P250 P250 P245 P245 P245 Orifice (LPG) P211 P211 P211 P209 P209 P209 Orifice (Nat) P200 P200 P200 P200 P200 P200 Orifice Fitting 11269 11269 11269 11269 11269...
  • Page 65: Fbb4 Variable Speed Blower Installation

    FBB4 VARIABLE SPEED BLOWER INSTALLATION Attention: Install blower assembly before connecting gas inlet 5. Insert blower assembly into interior, bottom of fireplace. supply line Position blower assembly behind gas valve, align notch on back of blower assembly with center screw on fireplace back Note: Junction box on right side of fireplace must be pre-wired at and push blower assembly against fireplace back.
  • Page 66: Junction Box Wiring Installation Instructions

    FBB4 VARIABLE SPEED BLOWER INSTALLATION FBB4 B L O W E R A S S E M B LY COMPLETE R7649 FAN CONTROL R4192 SPEED CONTROL KNOB R4186 SPEED CONTROL 110 VOLT AC JUNCTION BOX BLACK SWITCH WHITE GROUND SPEED CONTROL JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE...
  • Page 67: Accent Lamp

    ACCENT LAMP Your Luxury Direct Vent Gas Fireplace comes equipped with our COVER "Accent Lamp." The light has been pre-wired and is controlled from the Rheostat. If in the event the lamp or lens needs to be replaced, follow the instructions below: Unplug the Accent Lamp/transformer from the junction box inside the fireplace.
  • Page 68: Accessories

    ACCESSORIES The following accessory parts must be obtained from your Empire Comfort Systems dealer. If you need additional information contact your dealer. Simulated Stone Panels The simulated stone panels were designed to enhance the appearance of your fireplace, imitating the look of authentic DVP36XG masonry.
  • Page 69: Master Parts Distributor List

    For the current list, please click on the Master Parts button at www.empirecomfort.com. Please note: Master Parts Distributors are independent businesses that stock the most commonly ordered Original Equipment repair parts for Heaters, Grills, and Fireplaces manufactured by Empire Comfort Systems Inc. Star-Fire Distributors...
  • Page 70: Quick Reference Guide

    Empire Comfort Systems Web Site www.empirecomfort.com 918 Freeburg Avenue Belleville, Illinois 62220-2623 The Studio Series Direct Vent Gas Fireplace Heater MILLIVOLT STANDING PILOT: DVX36DP31(N,P)-1; DVX42DP31(N,P)-1 INTERMITTENT PILOT: DVX36DP71(N,P)-1; DVX42DP71(N,P)-1 REMOTE RF MODELS: DVX36DP91(N,P)-1; DVX42DP91(N,P)-1 Fireplace requires one of the following fronts:...
  • Page 71: Firebox Dimensions

    Empire Comfort Systems Web Site www.empirecomfort.com 918 Freeburg Avenue Belleville, Illinois 62220-2623 The Studio Series Direct Vent Gas Fireplace Heater MILLIVOLT STANDING PILOT: DVX36DP31(N,P)-1; DVX42DP31(N,P)-1 INTERMITTENT PILOT: DVX36DP71(N,P)-1; DVX42DP71(N,P)-1 REMOTE RF MODELS: DVX36DP91(N,P)-1; DVX42DP91(N,P)-1 Fireplace requires one of the following fronts:...
  • Page 72 Empire Comfort Systems Inc. EMPIRE EMPIRE 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. Comfort Systems www.empirecomfort.com...