INSTALLATION INSTRUCTIONS - GENERAL SAFETY INFORMATION

1.
This installation must conform with local codes or, in the
absence of local codes with NFPA54.
2. Provide adequate clearances around the product for
servicing and ensure there are no obstructions to the
combustion air intake situated at the back of the heater. Refer
to Page 14, Figures 6 through 10.
3. The appliance must be installed on a flat, solid continuous
surface (i.e. wood, metal, concrete). Please Note: Rough
or uneven surfaces can cause vibration or humming in the
heater.
4. The Mantis Power-Vent High-Effeciency Fireplace can be
installed in a wide variety of ways and will fit nearly any
room layout. It may be installed in a recessed position, framed
out into the room, or across a corner. For installation options
refer to page 14.
5. This appliance needs to be installed in such a way that the
heater can be removed at all times to service the heater ex-
changer and flue fan located in the rear section of the heater.
Model
Input BTU/HR (KW/H)
Height
Width
Depth
Gas Inlet (Pipe)
Electrical - Unit has a 5' (1.5 m) 3 pronged cordset for con-
nection to an approved 115 VAC 60 Hz maximum
AMPs - 5A wall receptacle.
Page 8

SPECIFICATIONS

F(F,I,W)28BM(N,P)
15,000 Rear - 13,000 Front
24 3/4"
28 3/16"
17 5/8"
3/8" Flair
Note:
Under no circumstances should the appliance be
installed under conditions which would not allow for
easy removal of the appliance to carry out routine
inspection and service to the appliance, to do so will
void the warranty.
Note:
On Single Wall flue pipe installations (imitation
zero clearance fireplace) a minimum of 2" (50.8 cm)
clearance must be provided at the rear of the heater to
enable the heater to get sufficient combustion air to the
air inlet located at the rear of heater. Refer to installation
instructions on page 14, Figures 6 through 10.
Note:
Where a mantel surround is being used on insert
installations and zero clearance fireplace installations,
the combustion air intake slot located in the top mantel
surround must have no obstructions to allow combustion
air to enter through the slot to the combustion air inlet
located at the back of the heater.
Accessories
Part Number
Description
TRW
Wall Thermostat - Wireless Remote
FRBTC
Battery Operated Remote with Thermostat
FRBTP
Battery Operated Remote with Programmable
Thermostat
TDV1
24 Digital Wall Thermostat
T24V
24 Volt Thermostat
TMV2
Two-Stage Thermostats
PVVK24H
Direct Vent 24" Vent Kit
PVVK48H
Direct Vent 48" Vent Kit
PVVK-SH
Single Flue Horizontal Vent Kit
PVVK-SV
Single Flue Vertical Vent Kit
PVVK-CFA
Flex Vent Kit
PVCT
Colinear Transition
PVVTC
Vertical Termination Cap - 1.5"
PVCA
Colinear Adapter
25700-1-0809