Pvvk-Cfa Flex Vent Kit - Empire Comfort Systems Mantis FF28BMN-1 Installation Instructions And Owner's Manual

Power-vent high-efficiency fireplace
Table of Contents

Advertisement

The flex vent kit is a flexible vent hose that is 42" in length. The flex vent kit will be used when installing a Mantis into an existing
fireplace. The flex vent kit can be cut down, but can only be cut from one end.
Cement PVC Joints
Once length is determined, install two (2) 10 x 1/2" screws into the adaptor assembly to secure the adaptor assembly to the flex hose.
Using PVC cement, cement all PVC joints of the flex vent kit to the remaining PVC vent run.
Determining Minimum Vent Height Above the Roof
WARNING: Major U.S. building codes specify minimum chimney and/or vent height above the rooftop. These minimum heights are
necessary in the interest of safety.
VENT CAP (SUPPLIED
WITH VENT KIT)
GALV. SHEET FLASHING
TO SEAL CHIMNEY
(SUPPLIED BY INSTALLER)
PVC PIPE SWV
(SUPPLIED BY INSTALLER)
(2) - 45 DEG. PVC BENDS
(SUPPLIED BY INSTALLER
IF NECCESSARY)
Figure 24 - Venting for Existing Fireplace Installation
Page 22
PVVK-CFA FLEX VENT KIT
Available from Empire Comfort Systems, Inc.
Cut End
Figure 23
CUT END
FLEXIBLE GAS
LINE
Cement PVC Joints
ROOF PITCH
H (Min.)
Flat to 6/12
12" (305 mm)
6/12 to 7/12
15" (381 mm)
Over 7/12 to 8/12
18" (457 mm)
Over 8/12 to 16/12
24" (610 mm)
Over 16/12 to 21/12
36" (914 mm)
FLEXIBLE
FLUE KIT
25700-1-0809