VERTICAL EXAMPLES FOR COLINEAR DIRECT VENT

In both vertical and horizontal colinear direct vent applications,
a colinear transition plate model PVCT can be used to minimize
clearances between intake and exhaust pipes.
For exhaust and intake air, cap pipes with any of the following:
Vertical termination cap (model #PVVTC), PTrap, or two 90º
elbows.
When transition plate (model PVCT) is used, two
termination caps (model PVVTC) may NOT be used.
TRANSITION PLATE
MODEL PVCT
Note: If transition plate (model PVCT) is used, the measurement
for center to center of the pipes will be 2.5". If the transition plate
(model PVCT) is not used, the measurement for center to center
of the pipes can be 3" to 24" maximum.
25700-1-0809
EXHAUST AIR INTAKE
2.5" - 24"
Figure 35
Page 27