1.
Remove lower louver panel by lifting up and pulling out.
2.
Main Electrical power supply must always be switched on to
the unit with the two burner switches in the off position (up)
before lighting the heater.
3.
Turn on main gas supply.
4.
Verify that main electrical supply is switched on by
checking the 115V AC power status display (Figures 66A and
65) indicator is on.
5. Burner selection: select low burn (front burner), medium
burn (rear burner), or high burn (both burners). Low burn
switch (Figure 65) controls the front burner only. Medium
burn switch (Figure 64) controls the rear burner only. When
both switches are down, they will activate both the low and
medium burners, which is the high setting.
6. Heater operating LED sequence (Front Display Panel).
Before starting ensure that the power L.E.D (Figure 66A)
is on and burner switches are off. Switch on the heater by
engaging the low and medium burner switch, this will
activate the pressure switch and the exhaust fan L.E.D
(Figure 66E) will be on. Also the two burner L.E.D's
REAR
BURNER
SWITCH
Figure 64
Figure 65
FRONT
THERMOSTAT
BURNER
DISPLAY MODE
BUTTON
SWITCH
Caution: When switching from the front burner to the rear burner, be sure to activate the rear burner first, then turn off the front burner.
When switching from rear burner to the front burner, be sure to activate the front burner first. Simple rule - always activate the
desired burner first, then switch the other burner off. If it is switched the wrong way, the burner(s) will go out and the heater
may need to be reset. Refer to page 48 - Resetting the Heater.
25700-1-0809

LIGHTING INSTRUCTIONS

Figure 63
A
(Figure 66C and 66D) will start flashing for 35 seconds
prior to ignition. Once both burners have ignited, the burner
L.E.D's will remain on. If you can't see flame on the rear
burner, but the burner L.E.D is on, then there will be flame
there which will become more visible as the heater warms up.
Once the heater warms up the low speed L.E.D (Figure 66F)
will light and the convection fan will blow warm air from
the heater. As the heater becomes warmer, the medium L.E.D
(Figure 66G) will come on. When the heater has reached its
highest operating temperature, all three L.E.D's will light up
and the convection fan will now be running at its high speed.
Refer to page 39 - Fan Operation. When the heater has been
running for some time, the water pump L.E.D (Figure 66B) may
come on to signal that the pump has been activated. Refer to
page 40 - Automatic Humidifier Operation.
Note: Three heat settings are available for operating your Mantis
heater - low, medium and high.
a.
Low setting (front burner only) - engage low burn switch
only (Figure 65)
b.
Medium setting (rear burner only) - engage medium
burner switch only (Figure 64)
c.
High setting (front and rear burners).
C
D
B
Figure 66
E
H
G
F