Vent Freezing Protection
When the vent pipe is exposed to temperatures below freezing
(i.e. when it passes through unheated spaces, chimneys, etc.) The
pipe must be insulated with 1/2 inch thick sponge rubber insula-
tion, Armaflex-type insulation or equivalent. Insulating pipe is im-
portant to avoid condensate icing.
For proper operation, the flue exhaust must extend 6 inches from
the outside wall before applying an elbow.
The Vent Adaptor Kits provide a transition from the fireplace to the
flue and inlet pipes. The Single Flue Horizontal Vent Kit (PVVK-
FC) provides a transition for the flue piping. No cement is required
to attach the adaptor to the fireplace. When installing the flue pip-
The PVVK-CFA Flex Vent Kit is a flexible vent hose that is 42" in length. The flex vent kit will be used when installing a
Mantis into an existing fireplace. The flex vent kit can be cut down, but can only be cut from one end.
Once length is determined, install two (2) 10 x 1/2" screws into the adaptor assembly to secure the adaptor assembly to
the flex hose. Using PVC cement, cement all PVC joints of the flex vent kit to the remaining PVC vent run.
Page 12
VENTING REQUIREMENTS
VENT ADAPTOR KITS
Figure 5
PVVK-CFA FLEX VENT KIT
Available from Empire Comfort Systems, Inc.
ing, use the appropriate primer and cement to permanently bond
the joints and pipes. Colinear Adaptor (part number PVCA) pro-
vides a transition for the inlet air. See Page 16.
Figure 4
Figure 6
30259-6-0314