PVCT COLINEAR TRANSITION VENT KIT
Note: Exhaust must be a minimum of 3" above air intake inlet.
OPTIONAL
EXHAUST
CAP
MODEL PVVTC
ORDER SEPARATE
PVC CEMENT
PVC CEMENT
TRANSITION PLATE
Flat Roof or Chimney Application
1.
Attach plate to chimney chase or flat roof with four (4) screws. Use outdoor sealant to seal transition plate to the roof or chimney
chase.
10 x 1 1/2" Hex Head Screw
2.
Check local codes to determine air intake height from roof. The minimum height for this application is 12".
3.
Cut 1 1/2" PVC pipe to correct height. Attach pipe, PTrap, and exhaust cap to plate. Glue all joints with PVC cement.
Figure 45
Horizontal Application
1.
Attach plate to outside wall with four (4) screws. Use outdoor sealant to seal transition plate to the wall.
2.
Cut 1 1/2" PVC pipe to correct length. The minimum length for this application is 9" for the exhaust and 6" for the air intake. Glue
all joints with PVC cement.
Page 30
Available from Empire Comfort Systems, Inc.
Figure 42 - Colinear Transition Plate
AIR INTAKE
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
3" MIN.
HEIGHT (MIN. 12")
OUTDOOR SEALER REQUIRED
Figure 43
PVC CEMENT
PVC CEMENT
TRANSITION PLATE
Figure 44
Note: Must maintain a minimum 3" between
exhaust outlet and air intake.
Figure 46
EXHAUST
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
AIR INTAKE
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
3" MIN.
HEIGHT (MIN. 12")
OUTDOOR SEALER REQUIRED