Installation; Getting Started; Pre-Installation Review - Kinetico Commercial Plus Softener Series Owner's Manual

Commercial plus softener series
Table of Contents

Advertisement

CP Softener Series Owners Manual
INSTALLATION
Getting Started
The following procedures have been developed to assist during the installation of your Kinetico Softener.
1:\ . ..
ill
ALL STATE AND LOCAL PLUMBING CODES MUST BE MET,
including, but not limited to:
...
-
Distances that equipment should be placed from the main
panel box and electrical outlets.
Air gaps that must be provided for all drain lines.
Pre-installation Review
Before beginning the installation of the Kinetico system, confirm system configuration to be installed and
components that have been ordered. Please review Kinetico specification sheet that includes required
components.
Review of the customer's facility is also recommended, especially critical operating data that could affect the
operation of the system:
Water pressure to the Kinetico system affects the performance during
regeneration. The Kinetico system will not operate properly if the inlet pressure
fluctuates below a dynamic pressure of 25 psi. This minimum pressure must be
maintained to the system at all times. Should the pressure fluctuate below this
level, a booster pump may be required.
Do not use on water pressure that exceeds 125 psi or water temperature that
exceeds 120°F.
Do not install the Kinetico Softener in an area where the temperature can cause
the unit to freeze. Damage to the system will result.
It is recommended that a WQA certified installer perform the installation. Failure
to install the system as instructed will void the warranty.
Proper ventilation must be provided when using PVC cleaner or glue.
A ladder should be used for all work overhead that would be beyond your natural
reach. If working continuously at a height of six feet or more, the appropriate
safety devices must be employed.
An appliance dolly should be used when transporting equipment on stairways.
When soldering, the following must be met and followed:
• LEAD FREE solder must be used.
• PVC containers and other flammable materials must be closed or
removed to prevent fire or explosions.
• Loose clothing (ie: shirttails, sleeves, etc.) should not be worn or should
be addressed before using a torch for soldering.
• The customer must be notified if you will be disabling smoke alarm(s)
during installation. Be sure to reconnect the smoke alarm(s).
• A scorch pad must be used to protect any surface that may be exposed to
a torch flame or excessive heat. Wear protective eyewear while installing
to prevent eye injury caused by splattering soldering materials or
metal/plastic shavings.
Rev. 08/09
Kinetico Incorporated
+
Corporate Headquarters
+
Newbury, Ohio 44065
+
440-564-9111
Product No. 11160D
Page -15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp 213s odCp 216s od

Table of Contents