Installation Of The Système - Kinetico MEDDALSOFT 11 User Manual

Systems for water softening
Table of Contents

Advertisement

• The place provided for its installation must have su-
fficient space for the device itself, its accessories, its
connections and for correct maintenance.
• The equipment must not be installed next to a heat
source or directly receiving a flow of hot air on it.
• A drain connection is necessary for the evacuation
of the regeneration water. The drain connection must
be with a free outlet. The diameter of this connection
must be at least 1". The maximum distance between the
softener and the drain outlet less than 6 meters.
Drain pipe
Drain pipe
4 cm.
Aeration
Underground drainage
Feed water pipe
• Do not raise the drain outlet above the level of the sof-
tener, as this may affect brine draw, resulting in improper
regeneration.
• If necessary, the drain outlet can be raised by a maximum
of 1.5 m. as long as the inlet pressure is above 4 bar.
• In case of higher heights and/or insufficient pressures,
contact your dealer.
• Under no circumstances will the equipment be installed
outdoors.
• The place where the equipment and faucet are installed
must meet adequate hygiene and sanitation conditions.
• Avoid external drops on equipment from pipes, drains and
so on.
• If the softened water supplies a hot water or steam gene-
rator, it will be necessary to install a non-return valve be-
tween the softener and the generator to prevent hot water
returns which could damage your softener..
• It is recommended to provide for the installation of water
sampling valves to be treated and treated, as close as pos-
sible to the softener.
• If there are quick-closing valves in the installation, install
an anti-water hammer device.
• The softener only works with a power of 12 volts at 50
hertz, powered by the transformer included in the equi-
pment. Be sure to use the transformer and plug it into a
220–240 V, 50Hz outlet. Similarly, it must be ensured that
the installation of the dwelling is duly protected by a circuit
breaker or fuse.
• If the daytime pressure exceeds 5.5 bar, the nighttime
pressure may exceed the maximum. Use a pressure redu-
cer if necessary. (A regulator can reduce the flow).
• It is recommended to install a silicopolyphosphate filter
at the outlet of the equipment, to protect the installation
from the corrosive tendency of softened water.
5.3 COMMISSIONING AND MAINTENANCE
The equipment must be disinfected periodically. To see
Section 8 for more information.
• Maintenance of the equipment must be carried out by
qualified technical personnel with an adequate attitude
and hygienic conditions. (For more information, contact
your after-sales service).
6. SYSTEM INSTALLATION
The installation of the softener must be carried out by
Drain pipe
qualified technical personnel. Follow the recommenda-
tions in Section 5.
4 cm.
Aeration
Since the device to be installed improves the quality of
the water that will be consumed and that it is conside-
red as food, all the tools that will be used for assembly
and installation must be clean and in no case can they
be contaminated or impregnated with fats, oils and
oxides; take extreme precautions in everything related
Sink outlet
to the materials that will be in contact with the water
to be consumed. (For more information, contact your
reseller).
6.1 TOOLS AND PARTS NEEDED
Before you start the installation, gather the necessary
tools. Follow the instructions in section 6.2.
If you use a copper tube stirred
If you are using threaded tubing
If you use PVC plastic
If you use other materials
Pipe cutter
Blowtorch Pliers
Tin-Silver.
Sandpaper or steel wool
Pipe cutter or steel saw
Threading machine
Pipe sealant
Pliers
Pipe cutter
Steel saw
Adjustable wrench
PVC glue
Pliers
Other suitable pipes and supports for
drinking water supply, according to
manufacturer's requirements and local
regulations