Control Disc Indicator; Levels 2 Through 6 - Kinetico Commercial Plus Softener Series Owner's Manual

Commercial plus softener series
Table of Contents

Advertisement

CP Softener Series Owners Manual
Control Disc Indicator
A visual indicator on top of the control disc (black dot) shows the state of the system at any time. The
control disc rotates clockwise. When the indicator dot is at the 12 o'clock position, the Remote Tank is in
service. When it is between the 12 o'clock and 6 o'clock positions, the Remote Tank is in regeneration.
When the indicator dot is at the 6 o'clock position, the Remote Tank is in service. When it is between the 6
o'clock and 12 o'clock positions, the Main Tank is in regeneration.
Levels 2 through 6
The lower valving section consists of Level 2, Level 3, Level 4 and Level 5
~
} Level 1
assemblies.
~
GI 1 I}
Levels 2 - 5
In the center, there is the regeneration control valve. This valve opens after 4 teeth
"-~
0
fi
liLeY_Eli 6\
'\ .;,/"\'-r' . on the control disc have engaged. This valve then opens, and powers the
regeneration cycle.
I
' i
r
\
...........
1 j
,
'
All of the other valves are pairs: one set for the Remote Tank and one set for the
I
II
Main Tank. For each media tank, there is an Inlet, Outlet, Drain and Check Stem
tJ
Valve. The Inlet, Outlet and Drain valves are all servo valves controlled by the control
I
{::iJ
disc. The Check Stems are simple one-way valves (check valves). Together, these
valves control the flow of water into and out of each media tank during service and
regeneration.
~-'a!!!Ii=i~_7t--urain Valves
Outlet Valves ,""--'7"'~r-il:~!;9"~~--""7lnlet Valves
Purge Valves
(OFFR enabled valves only)
Rev. 08/09
Kinetico Incorporated
+
Corporate Headquarters
+
Newbury, Ohio 44065
+
440-564-9111
Product No. 11160D
Page - 12