TECHNICAL DATA
REFRIGERATION SYSTEM
Compressor:
Compressor power:
Refrigerant gas:
Temperature control:
HYDRAULIC DIAGRAM

2. INSTALLATION

The installation of your Columbia Dispenser should be
carried out by sufficiently qualified personnel. Consult
your dealer if in doubt.
Caution: Since the device to be installed impro-
ves the quality of the water to be consumed, all
the tools to be used
used for assembly and installation must be clean and
must not be contaminated or impregnated with grea-
se, oil or oxides. Use tools exclusively for the cutting
of pipes, etc.
Attention: The work should be carried out with
a proper hygienic attitude and conditions, ex-
treme precautions in everything related to materials
and components that are going to be in.
contact with the water to be treated or consumed.
Caution: Avoid risks of external contamination
of equipment due to improper handling.
The use of gloves, hand sanitizing gel or washing
hands as often as necessary t h r o u g h o u t t h e
installation, commissioning and maintenance of the
equipment.
Sealed
70 W
R600a (22g)
Temperature probe
Install the inlet tap adapter (3) and connect the ¼" su-
pply tubing from the inlet valve to the IN (inlet) fitting on
the rear-bottom of the unit. Use appropriate tools and
sealants to ensure the tightness of the connections.
Before connecting the equipment to the power supply,
make sure that the equipment has been at rest for at
least 2 hours to avoid damage to the refrigeration sys-
tem.
It is necessary to remove the granulated carbon dust
from the filters that is generated during transport and
handling of the equipment and the corresponding car-
tridges.