Hard Water - Kinetico Commercial Plus Softener Series Owner's Manual

Commercial plus softener series
Table of Contents

Advertisement

CP Softener Series Owners Manual
Hard Water
Problem
Reason
Solution
1. Water meter disc
is not turning
0
0
Non-conforming meter drive pawl
Meter drive spring installed wrong
.
Replace meter drive pawl
Reinstall meter drive spring
0
No back pawl not installed
Install no back pawl
0
Damaged tooth on the meter disc
Replace meter disc
0
Damaged gear in the gearing stack
Re-gear Level 1 Assembly and
check allowable flow rates
2. The unit
will
not
0
Water meter disc is not turning
See number 1 above
go into automatic
regeneration
0
Control disc will not automatically
Replace regeneration start pawl
advance out of service position
0
Damaged teeth on control disc
Replace control disc
3. No vacuum in
0
Check stems missing or not working
Replace or add check stems
brine position
correctly
0
Plugged venturi
Clean out Level 3 venturi throat
and molded venturi nozzle (Do
not
use a paper clip!)
0
Plugged backwash flow control
Clean out backwash flow
control
0
Plugged brine elbow screen
Clean out brine elbow screen
4. Short salting
0
The brine drum is not level. The grid
Level the brine drum.
system allows a water level no more
than 1" above the grid.
If
the brine drum
is not level, it may exceed this.
5. Bridged salt in the
0
Salt has solidified in the drum
Carefully move the salt around
brine drum
to break up the mass of
solidified salt.
6. The by-pass is
0
An open by-pass allows water to flow
Close the by-pass
open
around the system without any
treatment at all
Rev. 08109
Kinetico Incorporated
+
Corporate Headquarters
+
Newbury. Ohio 44065
+
440-564-9111
Product No. 11160D
Page - 30