POST message
604
An error occurred during a diskette drive test.
Action: Take the following steps to correct the problem:
662
A diskette drive configuration error occurred.
Action: If you removed a diskette drive, make sure that the diskette drive setting is correct in the
If the problem remains, call for service.
962
A parallel port configuration error occurred.
Action: If you changed a hardware option, make sure that the parallel port setting is correct in the
If the problem remains, call for service.
11xx
An error occurred during the system-board serial port test.
Action: If you have a serial device attached to your computer, verify that the serial cable is
If the POST error message does not reappear, either the serial cable or the device is probably
failing. See the documentation that comes with the serial device for additional testing information.
If the POST error message reappears, call for service.
1162
The serial port configuration conflicts with another device in the system.
Action: Take the following steps to correct the problem:
1600
The Advanced System Management processor is not functioning.
Action: Take the following steps to correct the problem:
If the problem remains, call for service.
1601
An Advanced System Management Flash update is needed.
Action: Download and install the latest Advanced System Management flash update.
1800
A PCI adapter has requested a hardware interrupt that is not available.
Action: Take the following steps to correct the problem:
Table 3. POST error messages (continued)
76
IBM IntelliStation E ProTypes 6216 and 6226:User's Guide
1. Verify that the Configuration/Setup Utility program correctly reflects the type of diskette
drive that you have installed.
2. Run the diagnostic tests. If the diagnostic tests fail, call for service.
Configuration/Setup Utility program. If the setting is not correct, change it.
Configuration/Setup Utility program. If the setting is not correct, change it.
connected correctly. If it is, use the following procedure:
1. Turn off the computer.
2. Disconnect the serial cable from the serial port.
3. Wait five seconds; then, turn on the computer.
1. Make sure the IRQ and I/O port assignments needed by the serial port are available.
2. If all interrupts are being used by adapters, you might need to remove an adapter to
make an interrupt available to the serial port, or force other adapters to share an
interrupt.
1. Verify that the jumpers for the system-management processor are set correctly.
2. Disconnect the computer from all electrical sources, wait for 30 seconds, reconnect the
computer to the electrical sources, and restart the computer.
1. Make sure that the PCI adapter and all other adapters are set correctly in the
Configuration/Setup Utility program. If the interrupt resource settings are not correct,
change the settings.
2. If all interrupts are being used by other adapters, you might need to remove an adapter
to make an interrupt available to the PCI adapter, or force other adapters to share an
interrupt.
Description