Telnet Interface-Port 2005; Command Summary - Network Technologies VEEMUX SM-8X4-HDA Installation And Operation Manual

Veemux series audio/hd video matrix switch
Table of Contents

Advertisement

NTI AUDIO/HD VIDEO MATRIX SWITCH

Telnet Interface-Port 2005

For a software control type of telnet interface session (versus operator telnet control through port 2000 as described on page 14),
connect to the VEEMUX through the current IP address at port 2005. To do this, a connection to port 2005 must first be enabled
(see Web Setup on page 25). Then, with port 2005 enabled, use the command set below to control and acquire information from
the VEEMUX.
Notes:
If Port 2005 connection is idle for 10 seconds it will disconnect
Up to 2 active connections are allowed at the same time
After establishing the connection, the unit will answer with *<CR>. If the connection fails or there are already 2
connections established, it will answer with ?<CR>
Legend:
(All numbers must be two digits)
OP
:
Output Port (01-MAXOUTPUTS)
IP
:
Input Port (01-MAXINPUTS)
<CR>
:
Carriage Return (Hex 0xD)

Command Summary

Command String
Good Response
RU<CR>
ru OP,IP<CR>
RO OP<CR>
pc OP,IP<CR>
CS OP,IP<CR>
*<CR>
CA IP<CR>
*<CR>
SS 01<CR>
*<CR>
SS 00<CR>
*<CR>
SX<CR>
See details
AO OP<CR>
ac OP,IP<CR>
AS OP,IP<CR>
*<CR>
AA IP<CR>
*<CR>
AV OP,VV<CR>
*<CR>
AM OP,MM<CR>
*<CR>
AR OP<CR>
ar OP:MM,VV<CR>
XX<CR>
*<CR>
A <CR> (carriage return, 0x0D) is considered to be the end of the command string. If a string exceeds 16 characters, an end of
string will be inserted automatically to avoid buffer overflow. An eventual <LF> (line feed, new line, 0x0A) after a <CR> will be
ignored. A bad string will always be responded to with the ASCII character '?' followed by a <CR>.
Description
Read unit size
Read connection for OP
Connect OP to IP
Connect all outputs to IP
Enable auto-status mode
Disable auto-status mode
Examine connections
Read audio connection for OP
Connect audio OP to IP
Connect all audio outputs to IP
Set audio volume for OP
Set audio mute status for OP
Read mute and volume for OP
Close connection
16