Telnet Interface - Network Technologies SM-nXm-C5AV-LCD Installation And Operation Manual

Veemux series audio/video matrix switch via cat5
Table of Contents

Advertisement

NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH VIA CAT5

Telnet Interface

The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server
listens on port 2000. To access the telnet interface, using the current IP address type the following in a command shell:
telnet 192.168.1.1 2000
The VEEMUX will prompt the user for a password. The user must enter the password followed by <Enter>.
The default factory password is "admin".
With a proper password sent the VEEMUX will respond with:
Password Successful
Connection Established
The following commands are now available:
Command
H(elp) or
Displays the list of
h(elp)
<Ctrl>-<X>
(see note 4 below)
Connection to host lost.
CS nn,mm
CA nn
RO nn
*<CR>mm<CR>
CC nn
*<CR>nn<CR>
RC nn
*<CR>nn<CR>
CB nn
RV 00
*<CR>string\0<CR>
RU
*<CR>nn,mm<CR>
User is prompted to
CP
introduce the password
Notes:
1. The commands must be typed exactly as shown in the chart. The commands are case sensitive.
2. If a mistake is made, the user must backspace to the beginning and completely retype the command.
3. If a command is sent that the VEEMUX does not recognize or exceeds the configuration of the switch, the reply
"?" may be received. Check the command syntax and try again.
4. To quit the telnet session, press the keyboard keys <Ctrl><X> .
Reply
commands
Good Bye.
*<CR>
Connect one Output Port (nn) To one Input Port (mm)
*<CR>
Returns the number of the input (mm) connected to output nn
Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)
*<CR>
Returns the number of inputs(nn) and the number of outputs (mm)
twice
Description
Help
Quit telnet session
Connect All Outputs To Input
Read Connection For Output.
Save Matrix Connections Into Memory Bank nn
nn should be between 00 and 09
Restore Matrix Connections From Memory Bank nn
nn should be between 00 and 09
Factory default is 9,600.
Read NTI Version String
Read Unit Size
Change password