Ethernet Operations; Setup Options; Ethernet Control; Telnet Interface-Port 2000 - Network Technologies VEEMUX SM-8X4-HDA Installation And Operation Manual

Veemux series audio/hd video matrix switch
Table of Contents

Advertisement

NTI AUDIO/HD VIDEO MATRIX SWITCH

Ethernet Operations

Key
Selection
1)
Set Unit IP Address
2)
Set Unit Subnet Mask
3)
Set Unit Default Gateway
4)
Set Unit Website Timeout
5)
Read Unit IP Address
6)
Read Unit Subnet Mask
7)
Read Unit Default Gateway
8)
Read Unit Website Timeout

Setup Options

Key
Selection
1)
Select Com port current:
(COM1:)
2)
Select Baud rate current:
(9600)
3)
Set unit Address current:
(1)
For any selection that requires user input, the user is prompted. When commands are sent to the matrix unit, the command string
and matrix unit responses are echoed to the screen. All commands generated by the program are formatted according to the
information provided in sections above. If any transmission problems are detected, an error message is displayed.
Press <Esc> or <Enter> to back out to the main menu and press again to exit.

ETHERNET CONTROL

Telnet Interface-Port 2000

The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server
listens on ports 2000 and 2005. Port 2000 is for an operator telnet session while port 2005 (must be enabled) is intended for a
software control type session (see page 16). For operator telnet control using the telnet interface and the current IP address,
type the following in a command shell:
telnet 192.168.1.30 2000
The VEEMUX-A will prompt the user for a password. The user must enter the password followed by <Enter>.
The factory default password is "admin".
With a proper password sent the VEEMUX-A will respond with:
Password Successful
Connection Established
Description
- enter the desired IP address in xxx.xxx.xxx.xxx format
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted
- enter the desired IP address in xxx.xxx.xxx.xxx format
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted
- enter the desired default gateway
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted
- set the website timeout; timeout = numeric string of timeout in seconds
- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800
- read the unit IP address in xxx.xxx.xxx.xxx format
- read the unit subnet mask in xxx.xxx.xxx.xxx format
- read the unit default gateway in xxx.xxx.xxx.xxx format
- read the current website timeout period in seconds
- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800
Description
- select PC serial port
- the current PC serial port is displayed in parentheses
- select PC serial port baud rate
- the current baud rate is displayed in parentheses
- select the unit address
- the current address is displayed in parentheses
14
0 = no timeout
0 = no timeout