Network Technologies VEEMUX SM-8X4-HDA Installation And Operation Manual page 19

Veemux series audio/hd video matrix switch
Table of Contents

Advertisement

NTI AUDIO/HD VIDEO MATRIX SWITCH
The following commands are now available:
Command
Reply
H(elp) or
Displays the list of commands
h(elp)
CS nn,mm
*<CR>
CA nn
*<CR>
RO nn
*<CR>mm<CR>
CC nn
*<CR>nn<CR>
RC nn
*<CR>nn<CR>
CB nn
*<CR>
RV 00
*<CR>string<CR>
RU
*<CR>nn,mm<CR>
RS
*<CR>
AS nn,mm
*<CR>
AA nn
*<CR>
AO nn
*<CR>nn<CR>
AM nn,mu
*<CR>
AV nn,vv
*<CR>
AR nn
*<CR>MU,VV<CR>
Ss nn,dwt
*<CR>
*<CR>
Gs nn
dwt<CR>
Sa nn,mm
*<CR>
Sc nn
*<CR>
S+ nn,mm
*<CR>
S- nn,mm
*<CR>
Sx nn
*<CR>oooxoxxxooooxxx<CR>
User is prompted to introduce the
CP
password twice
<Ctrl>-<X>
Good Bye.
(see note 4 below)
Connection to host lost.
Notes:
1. The commands must be typed exactly as shown in the chart. The commands are case sensitive.
2. If a mistake is made, the user must backspace to the beginning and completely retype the command.
3. If a command is sent that the VEEMUX-A does not recognize or exceeds the configuration of the switch, the
reply "?" may be received. Check the command syntax and try again.
4. To quit the telnet session, press the keyboard keys <Ctrl><X>.
Description
Help
Connect One Output nn To Input mm
Connect All Outputs To Input nn
Read Connection For Output.
Returns the number of the input mm connected to output nn
Save Matrix Connections Into Memory Bank nn
nn should be between 00 and 99
Restore Matrix Connections From Memory Bank nn
nn should be between 00 and 99
Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)
Factory default is 9600.
Read NTI Version String
Read Unit Size
Returns the number of inputs mm and the number of outputs mm
Reset Unit
Connect audio input mm to output mm
Connect audio input nn to all outputs
Read audio connection for output nn
Set mute state for output nn
mu(te State) = (00=UNMUTE, 01=MUTE)
Set volume level for output nn
vv is a value between 00 to 99 (see chart page 12)
Read mute, volume for output nn
MU is 00 if the port is UNMUTED, MU is 01 if the port is MUTED.
VV is a value between 00 to 99 (see chart page 12)
Set value of Scan Mode dwell time (see page 9) for specific Output
(nn)
dwt = 000-255 (seconds)
000= disable Scan Mode
Read set Scan Mode dwell time value (dwt) for specific Output (nn)
in seconds (see also "Scan Mode" on page 9)
Set scan list of individual output nn to all inputs mm
Clear scan list of individual output nn
Add input mm to Scan List of output nn
Remove input mm from Scan List of output nn
Display the Scan List of output nn (o=skip x=don't skip)
Change password- five (5) characters minimum
Quit telnet session
15