Installing the System into a Rack

This section provides information on installing the SuperServer 6016T-T into a
rack. If the system has already been mounted into a rack, you can skip ahead to
Sections 2-5 and 2-6.
There are a variety of rack units on the market, which may mean the assembly
procedure will differ slightly. The following is a guideline for installing the unit into
a rack with the rack rails provided with the system. You should also refer to the
installation instructions that came with the rack unit you are using.

Identifying the Sections of the Rack Rails

You should have received two rack rail assemblies with the SuperServer 6016T-T.
Each of these assemblies consist of two sections: an inner fi xed chassis rail that
secures to the unit (A) and an outer fi xed rack rail (B) that secures to the rail
brackets. A sliding rail guide sandwiched between the two should remain attached
to the fi xed rack rail (see Figure 2-1). The A and B rails must be detached from
each other to install.
To remove the fi xed chassis rail (A), pull it out as far as possible - you should hear
a "click" sound as a locking tab emerges from inside the rail assembly and locks
the inner rail. Then depress the locking tab to pull the inner rail completely out. Do
this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
Pull out the inner
rail(to be attached
on the chassis)
Outer rail (to be
installed in the
rack)
A
2-4
B