SUPERSERVER 2027TR-D70RF(+) USER'S MANUAL
2-5
Installing the System into a Rack
This section provides information on installing the chassis into a rack unit with the
rails provided. There are a variety of rack units on the market, which may mean
that the assembly procedure will differ slightly from the instructions provided. You
should also refer to the installation instructions that came with the rack unit you
are using.
Note: This rail will fit a rack between 26.5" and 36.4" deep.
Separating the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit (Figure
2-1). Each assembly consists of two sections: an inner fixed chassis rail that secures
directly to the server chassis and an outer fixed rack rail that secures directly to
the rack itself.
Figure 2-1. Identifying the Outer Rail, Middle Rail and Inner Rails
Rail Assembly
(Shown with Rails
Retracted)
This Side Faces
(Left Rail Assembly Shown)
Outward
2-4
Outer Rail
Middle Rail
Locking Tab
Inner Rail