Supero SuperServer 6016T-6RFT+ User Manual

Supero SuperServer 6016T-6RFT+ User Manual

1.0a
Hide thumbs Also See for SuperServer 6016T-6RFT+:
Table of Contents

Advertisement

Quick Links

S
UPER
®
S
S
6016T-6RFT+
UPER
ERVER
S
S
6016T-6RF+
UPER
ERVER
USER'S MANUAL
1.0a

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SuperServer 6016T-6RFT+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Supero SuperServer 6016T-6RFT+

  • Page 1 UPER ® 6016T-6RFT+ UPER ERVER 6016T-6RF+ UPER ERVER USER’S MANUAL 1.0a...
  • Page 2 This product, including software and docu- mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
  • Page 3: About This Manual

    Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6016T- 6RFT+/6016T-6RF+. Installation and maintenance should be performed by expe- rienced technicians only. Manual Organization Chapter 1: Introduction The fi...
  • Page 4 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X8DTU-6TF+/X8DTU-6F+ serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi...
  • Page 5 Preface Notes...
  • Page 6: Table Of Contents

    System Power ....................1-3 Hard Drives ..................... 1-3 PCI Expansion Slots ..................1-4 Front Control Panel ..................1-4 Cooling System ....................1-4 Contacting Supermicro ..................1-6 Chapter 2 Server Installation Overview ......................2-1 Unpacking the System ..................2-1 Preparing for Setup ..................2-1 Choosing a Setup Location ................
  • Page 7 Table of Contents Installing the Server into a Telco Rack ............2-6 Checking the Serverboard Setup ..............2-8 Chapter 3 System Interface Overview ......................3-1 Control Panel Buttons ..................3-1 Control Panel LEDs ..................3-2 Drive Carrier LEDs ..................3-3 Chapter 4 Standardized Warning Statements for AC Systems About Standardized Warning Statements ............
  • Page 8 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual X8DTU-6TF+/X8DTU-6F+ Quick Reference ..........5-14 Connector Defi nitions ..................5-15 Jumper Settings .................... 5-23 5-10 Onboard Indicators ..................5-25 5-11 SATA Port Connections ................. 5-27 5-12 Installing Software ..................5-28 SuperDoctor III ....................5-29 5-13 Onboard Battery ....................
  • Page 9: Chapter 1 Introduction

    SC819TQ-R700U 1U server chassis and the X8DTU-6TF+/X8DTU-6F+ dual processor serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.supermicro.com). In addition to the serverboard and chassis, various hardware components have been included with the 6016T-6RFT+/6016T-6RF+, as listed below: •...
  • Page 10: Serverboard Features

    DDR3-1333/1066/800 SDRAM. Please refer to Chapter 5 for installing memory. The X8DTU-6TF+/X8DTU-6F+ is a specially-designed serverboard that features Supermicro's UIO (Universal I/O) technology. UIO serverboards have a PCI Ex- press 2.0 x8 slot that can support any one of several types of UIO card types to add SAS ports, SATA ports, additional LAN ports or other additional functions to the serverboard.
  • Page 11: Rear I/O Ports

    Chapter 1: Introduction 10 supported (RAID 5 is supported with Windows OS only). The SATA drives are hot-swappable units. Note: You must have RAID set up to enable the hot-swap capability of the SATA drives. Documentation on RAID setup guidelines can be found on our web site. Rear I/O Ports The color-coded I/O ports include one COM port, a VGA (monitor) port, two USB 2.0 ports, PS/2 mouse and keyboard ports, one dedicated IPMI LAN port and two...
  • Page 12: Pci Expansion Slots

    PCI-E x4 card (in a x8 slot). The RSC- R1UU-2E8 is located on the left side of the chassis and supports two PCI-E x8 add-on cards. See our web site for details (http://www.supermicro.com/products/ nfo/UIO.cfm). See section 5-6 of this manual for details.
  • Page 13: System Block Diagram

    Chapter 1: Introduction Figure 1-1. Intel 5520 + IOH-36D/ICH10R Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. Processor#0 Processor#1 PORT1 PORT1 PORT0 PORT0 Gen2 x16 PORT 7,8,9,10 Gen2 x4 PORT PORT Gen2 x8 PORT CLINK...
  • Page 14: Contacting Supermicro

    Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 15: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter provides a quick setup checklist to get your 6016T-6RFT+/6016T-6RF+ up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory pre-installed.
  • Page 16: Warnings And Precautions

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display Units. Warnings and Precautions Rack Precautions •...
  • Page 17: Rack Mounting Considerations

    Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (Tmra).
  • Page 18: Installing The System Into A Rack

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Installing the System into a Rack This section provides information on installing the 6016T-6RFT+/6016T-6RF+ into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly.
  • Page 19: Installing The Outer Rails

    Chapter 2: Server Installation Installing the Outer Rails Installing the Outer Rails to the Rack 1. Measure the distance from the front rail to the rear rail of the rack. 2. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail.
  • Page 20: Installing The Server Into A Telco Rack

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Installing the Server into the Rack Installing the Chassis into a Rack (Figure 2-3) 1. Confi rm that chassis includes the inner rails and rail extensions . Also, confi rm that the outer rails are installed on the rack. 2.
  • Page 21 Chapter 2: Server Installation Figure 2-3. Installing the Server into a Rack...
  • Page 22: Checking The Serverboard Setup

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Checking the Serverboard Setup After you install the system in the rack, you will need to open the top cover to make sure the serverboard is properly installed and all the connections have been made. Accessing the Inside of the System 1.
  • Page 23 Chapter 2: Server Installation Figure 2-4. Accessing the Inside of the System...
  • Page 24: Checking The Drive Bay Setup

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the hard drives and backplane have been properly installed and all connections have been made. Checking the Drives 1. All drives are accessable from the front of the server. The hard disk drives can be installed and removed from the front of the chassis without removing the top chassis cover.
  • Page 25: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview There are several LEDs on the control panel as well as others on the hard drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi...
  • Page 26: Control Panel Leds

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Control Panel LEDs The control panel located on the front of the SC819TQ chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
  • Page 27: Drive Carrier Leds

    Chapter 3: System Interface Power Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating. Drive Carrier LEDs • Green: Each SAS/SATA drive carrier has a green LED. When illuminated, this green LED indicates drive activity.
  • Page 28 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Notes...
  • Page 29: Chapter 4 Standardized Warning Statements For Ac Systems

    Only certifi ed technicians should attempt to install or confi gure components. Read this appendix in its entirety before installing or confi guring components in the Supermicro chassis. These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Defi nition Warning! This warning symbol means danger.
  • Page 30 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
  • Page 31 Warning Statements for AC Systems ‫ﺟﺴﺪﻳﺔ‬ ‫ﺍﺻﺎﺑﺔ‬ ‫ﺗﺘﺴﺒﺐ ﻓﻲ‬ ‫ﺣﺎﻟﺔ ﻳﻤﻜﻦ ﺃﻥ‬ ‫ﺍﻧﻚ ﻓﻲ‬ ‫ﺧﻄﺮ‬ ‫ﻳﻌﻨﻲ‬ ‫ﻫﺬﺍ ﺍﻟﺮﻣﺰ‬ !‫ﺗﺤﺬﻳﺮ‬ ‫ﺍﻟﺪﻭﺍﺋﺮ‬ ‫ﺑﺎﻟﻤﺨﺎﻁﺮ ﺍﻟﻨﺎﺟﻤﺔ ﻋﻦ‬ ‫ﻦ ﻋﻠﻰ ﻋﻠﻢ‬ ، ‫ﻛ‬ ‫ﻣﻌﺪﺍﺕ‬ ‫ﺗﻌﻤﻞ ﻋﻠﻰ ﺃﻱ‬ ‫ﻗﺒﻞ ﺃﻥ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫ﺣﻮﺍﺩﺙ‬ ‫ﺃﻱ‬ ‫ﻭﻗﻮﻉ‬ ‫ﻤﻨﻊ‬ ‫ﻟ‬ ‫ﺍﻟﻮﻗﺎﺋﻴﺔ‬...
  • Page 32: Installation Instructions

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
  • Page 33: Circuit Breaker

    Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. 警告 此产品的短路(过载电流)保护由建筑物的供电系统提供,确保短路保护设备的额定电 流不大于250V,20A。 警告 此產品的短路(過載電流)保護由建築物的供電系統提供,確保短路保護設備的額定電 流不大於250V,20A。...
  • Page 34: Power Disconnection Warning

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A. Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components.
  • Page 35 Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché...
  • Page 36: Equipment Installation

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Equipment Installation Warning! Only trained and qualifi ed personnel should be allowed to install, replace, or service this equipment. 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifi ziertem Personal gestattet werden. ¡Advertencia! Solamente el personal califi...
  • Page 37: Restricted Area

    Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalifi ceerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
  • Page 38: Battery Handling

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ .('‫כלי אבטחה בלבד )מפתח, מנעול וכד‬ ‫ﻣﺤﻈﻮﺭﺓ‬ ‫ﻣﻨﺎﻁﻖ‬ ‫ﻟﺘﺮﻛﻴﺒﻬﺎ ﻓﻲ‬ ‫ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ‬ ‫ﺗﺨﺼﻴﺺ‬ ‫ﺗﻢ‬ ،‫ﺃﺩﺍﺓ ﺧﺎﺻﺔ‬ ‫ﻣﻦ ﺧﻼﻝ ﺍﺳﺘﺨﺪﺍﻡ‬ ‫ﻓﻘﻂ‬...
  • Page 39 Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 40: Redundant Power Supplies

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 41: Backplane Voltage

    Chapter 4: Warning Statements for AC Systems ‫ﺍﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺑﻮﺣﺪﺍﺕ‬ ‫ﻋﺪﺓ ﺍﺗﺼﺎﻻﺕ‬ ‫ﺠﻬﺎﺯ‬ ‫ﺍﻟ‬ ‫ﻳﻜﻮﻥ ﻟﻬﺬﺍ‬ ‫ﻗﺪ‬ ‫ﺍﻟﻜﻬﺮﺑﺎء‬ ‫ﻋﻦ‬ ‫ﻮﺣﺪﺓ‬ ‫ﺍﻟ‬ ‫ﻟﻌﺰﻝ‬ ‫ﻛﺎﻓﺔ ﺍﻻﺗﺼﺎﻻﺕ‬ ‫ﻳﺠﺐ ﺇﺯﺍﻟﺔ‬ Waarschuwing Deze eenheid kan meer dan één stroomtoevoeraansluiting bevatten. Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken. Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is...
  • Page 42: Comply With Local And National Electrical Codes

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual ‫מתח בפנל האחורי‬ !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ .‫העבודה‬ ‫ﺍﻟﻠﻮﺣﺔ‬ ‫ﺃﻭﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ‬ ‫ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ‬ ‫ﻣﻦ‬ ‫ﺧﻄﺮ‬ ‫ﻫﻨﺎﻙ‬ ‫ﻫﺬﺍ ﺍﻟﺠﻬﺎﺯ‬ ‫ﺧﺪﻣﺔ‬ ‫ﻛﻦ ﺣﺬﺭﺍ ﻋﻨﺪ‬ ‫ﻳﻌﻤﻞ‬ ‫ﺍﻟﻨﻈﺎﻡ‬ ‫ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ‬ Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 43: Product Disposal

    Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫התקנת‬ ‫ﺍﻟﻤﺘﻌﻠﻘﺔ‬ ‫ﺍﻟﻤﺤﻠﻴﺔ ﻭﺍﻟﻮﻁﻨﻴﺔ‬ ‫ﻘﻮﺍﻧﻴﻦ‬ ‫ﻳﺠﺐ ﺃﻥ ﻳﻤﺘﺜﻞ ﻟﻠ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬...
  • Page 44: Hot Swap Fan Warning

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
  • Page 45 Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
  • Page 46: Power Cable And Ac Adapter

    fi re. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certifi ed cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only. 警告...
  • Page 47 Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifi és qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement.
  • Page 48 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Notes 4-20...
  • Page 49: Chapter 5 Advanced Serverboard Setup

    Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X8DTU-6TF+/X8DTU-6F+ serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter.
  • Page 50: Processor And Heatsink Installation

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Processor and Heatsink Installation Warning: When handling the processor, avoid placing direct pressure on the label area of the fan. Also, do not place the serverboard on a conductive surface, which can damage the BIOS battery and prevent the system from booting up. IMPORTANT! Always connect the power cord last and remove it fi...
  • Page 51 Chapter 5: Advanced Serverboard Setup 1. After removing the plastic cap, use your thumb and the index fi nger to hold the CPU at the north and south center edges. 2. Align the CPU key (the semi-circle cutout) with the socket key (the notch below the gold color dot on the side of the socket).
  • Page 52: Installing The Heatsink

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Installing the Heatsink 1. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the retention mechanism. Thermal Grease 2. Remove the thin layer of protective fi...
  • Page 53: Removing The Heatsink

    Chapter 5: Advanced Serverboard Setup Removing the Heatsink Warning: We do not recommend removing the CPU or the heatsink. If you do need to remove the heatsink, please follow the instructions below to prevent damage to the CPU or other components. 1.
  • Page 54: Connecting Cables

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed in preconfi...
  • Page 55: I/O Ports

    Chapter 5: Advanced Serverboard Setup Figure 5-1. Front Control Panel Header Pins (JF1) Ground x (key) x (key) Power LED 3.3V HDD LED UID Switch/Vcc NIC1 Link LED NIC1 Active LED NIC2 Link LED NIC2 Active LED Blue: OH/Fan Fail/Power Fail/UID LED Red: (Blue LED Cathode) Power Fail LED 3.3V...
  • Page 56: Installing Memory

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Installing Memory Note: Check the Supermicro web site for recommended memory modules. CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Installing DIMMs 1. Insert the desired number of DIMMs into the memory slots, starting with slot P1-DIMM1A.
  • Page 57 Chapter 5: Advanced Serverboard Setup Memory Population for Optimal Performance With One CPU (CPU1) Installed P1-DIMMs To Populate P1-DIMMs Branch 0 Branch 1 Branch 2 3 DIMMs P1-1A P1-2A P1-3A 6 DIMMs P1-1A P1-1B P1-2A P1-2B P1-3A P1-3B 9 DIMMs P1-1A P1-1B P1-1C...
  • Page 58 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual UDIMM Population with 5500 Processors Installed DIMM DIMMs DIMM Type (Unb.= Speeds (in MHz) Ranks per DIMM Slots per Populated Unbuffered) (any combination; Channel per Channel SR=Single Rank, DR=Dual Rank, QR=Quad Rank) Unb. DDR3 ECC/Non-ECC 800,1066,1333 SR or DR Unb.
  • Page 59 Chapter 5: Advanced Serverboard Setup • 1.35V DIMMs 1.35V RDIMM Population with 5600 Processors Installed DIMM DIMMs DIMM Type Speeds (in MHz) Ranks per DIMM Slots per Populated (Reg.=Registered) (any combination; Channel per Channel SR=Single Rank, DR=Dual Rank, QR=Quad Rank) Reg.
  • Page 60: Adding Pci Cards

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Adding PCI Cards PCI Expansion Slots The X8DTU-6TF+/X8DTU-6F+ has one Universal PCI slot. Riser cards installed to the system allow you to add PCI expansion cards (see below). The SC819TQ- R700U chassis can support the use of two standard size (full-height, full-length) expansion cards and one low-profi...
  • Page 61: Serverboard Details

    Chapter 5: Advanced Serverboard Setup Serverboard Details Figure 5-4. SUPER X8DTU-6TF+/ Layout LED7 USB0/1 COM1 LAN2 LAN1 LED2 IPMI LAN Intel 82576 Ethernet JPL1 Speaker Intel 82599 Controller Ethernet Controller Battery JPTLAN FAN8/CPU1 SAS BBU CPU1 SAS0~3 SAS4~7 LSI 2108 LED6 Controller LED5...
  • Page 62: X8Dtu-6Tf+/X8Dtu-6F+ Quick Reference

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual X8DTU-6TF+/X8DTU-6F+ Quick Reference Jumper Description Default Setting Clear CMOS See Section 5-9 JBT1 C1/JI SMB to PCI-E Slots Open (Disabled) JPG1 VGA Enable Pins 1-2 (Enabled) JPL1 LAN1/LAN2 Enable/Disable Pins 1-2 (Enabled) JPS1 SAS Enable/Disable Pins 1-2 (Enabled) JPTLAN TLAN1/2 Enable/Disable...
  • Page 63: Connector Defi Nitions

    Chapter 5: Advanced Serverboard Setup Description LED1 Power LED LED2 UID LED LED3 BMC Heartbeat LED LED4 SAS Activity LED LED5 SAS Heartbeat LED LED6 SAS Error LED LED7 UID LED Connector Defi nitions ATX Power 24-pin Connector Pin Defi nitions Pin# Defi...
  • Page 64 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual NMI Button NMI Button Pin Defi nitions (JF1) The non-maskable interrupt button Pin# Defi nition header is located on pins 19 and 20 Control of JF1. Refer to the table on the right Ground for pin defi nitions. Power LED Power LED Pin Defi...
  • Page 65 Chapter 5: Advanced Serverboard Setup Overheat (OH)/Fan Fail/PWR Fail/ OH/Fan Fail/ PWR Fail/Blue_UID UID LED LED Pin Defi nitions (JF1) Pin# Defi nition Connect an LED to pins 7 and 8 of Blue_LED Cathode (UID) JF1 to provide advanced warning of OH/Fan Fail/PWR Fail/UID LED chassis overheating or fan failure.
  • Page 66 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Serial Port Pin Defi nitions Serial Ports Pin # Defi nition Pin # Defi nition The COM1 serial port is located on the I/O backplane. COM2 is a header on the serverboard (see serverboard layout for location). See the table on the right for pin defi...
  • Page 67 Chapter 5: Advanced Serverboard Setup Chassis Intrusion Chassis Intrusion Pin Defi nitions A Chassis Intrusion header is located Pin# Defi nition at JL1. Attach the appropriate cable to Intrusion Input inform you of a chassis intrusion. Ground PS/2 Keyboard and Mouse Ports Pin Defi...
  • Page 68 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual IPMB Pin Defi nitions IPMB Pin# Defi nition A System Management Bus header for Data IPMI 2.0 is located at IPMB. Connect Ground the appropriate cable here to use the Clock IPMB I C connection on your system. No Connection DOM Power Connector DOM PWR...
  • Page 69 Chapter 5: Advanced Serverboard Setup UIO Power Connector Universal I/O Power Connector Pin Defi nitions A Universal I/O power connector Pin# Defi nition Pin # Defi nition (UIOP) is located next to the UID P3V3 button. This is a required connection P3V3 for the riser cards installed on the P3V3...
  • Page 70 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Trusted Platform Module (TPM) Pin Defi nitions Pin# Defi nition Pin # Defi nition LPC Clock Trusted Platform Module Header LPC FRAME# A Trusted Platform Module header LPC Reset# +5V (X) (JTPM) is located next to the COM2 LAD3 LAD2 connection.
  • Page 71: Jumper Settings

    Chapter 5: Advanced Serverboard Setup Jumper Settings Explanation of Jumpers To modify the operation of the serverboard, jumpers can be used Connector to choose between optional settings. Pins Jumpers create shorts between two pins to change the function of the Jumper connector.
  • Page 72 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual LAN/TLAN Enable/Disable LAN Enable/Disable Change the setting of jumper JPL1 to Jumper Settings enable or disable the LAN1 and LAN2 Jumper Setting Defi nition onboard Ethernet (RJ45) ports and Pins 1-2 Enabled JPTLAN to enable the 10 Gb LAN Pins 2-3 Disabled ports on the X8DTU-6TF+.
  • Page 73: 5-10 Onboard Indicators

    Chapter 5: Advanced Serverboard Setup 5-10 Onboard Indicators LAN LEDs Activity LED Link LED The Ethernet ports (located beside the VGA port) have two LEDs. On each Gigabit LAN port, one LED indicates LAN LED activity when blinking while the other Connection Speed Indicator LED may be green, amber or off to LED Color...
  • Page 74 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual BMC Heartbeat LED BMC Heartbeat LED A BMC heartbeat LED is located at State Defi nition LED3 on the serverboard. When LED3 Blink- BMC: Normal is blinking, the BMC is functioning normally. SAS Activity & SAS Heartbeat LEDs A SAS Activity LED (LED 4) and a SAS SAS Activity &...
  • Page 75: 5-11 Sata Port Connections

    Chapter 5: Advanced Serverboard Setup 5-11 SATA Port Connections SATA Port Pin Defi nitions SATA Ports Pin # Defi nition Ground There are six Serial ATA Ports (I- SATA0~I-SATA 5) on the serverboard, which are suppor ted by the Intel ICH10R South Bridge See the table Ground on the right for pin defi...
  • Page 76: 5-12 Installing Software

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. After accessing the ftp site, go into the CDR_Images directory and locate the ISO fi...
  • Page 77: Superdoctor Iii

    Chapter 5: Advanced Serverboard Setup SuperDoctor III The SuperDoctor® III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program allows you to monitor the environment and operations of your system.
  • Page 78: 5-13 Onboard Battery

    ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Figure 5-7. SuperDoctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/soft- ware/SuperDoctorIII.cfm. For Linux, we recommend that you use the SuperDoctor II application instead.
  • Page 79: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC819TQ chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step.
  • Page 80: Control Panel

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Figure 6-1. Chassis: Front and Rear Views Slim DVD-ROM Control Panel Hard Drive Bays (4) Power Supplies IPMI LAN USB Ports PCI Expansion Slots (w/riser cards) Mouse/Keyboard Ports COM1 Port VGA Port Ethernet (LAN) Ports* *The 6016T-6RF+ has two 1 Gb Ethernet ports while the 6016T-6RFT+ has two 1 Gb and two 10 Gb ports.
  • Page 81: System Fans

    3. Replace the failed fan with an identical 4-cm, 12 volt fan (available from Supermicro: p/n FAN-0086L4). 4. Push the new fan into the vacant space in the housing while making sure the arrows on the top of the fan (indicating air direction) point in the same direc- tion as the arrows on the other fans.
  • Page 82: Accessing The Drive Bays

    Note: Only a "slim" DVD-ROM drive will fi t into the 6016T-6RFT+/6016T-6RF+. Warning: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web site at http://www.supermicro.com/products/nfo/storage.cfm...
  • Page 83: Hard Drive Installation

    Chapter 6: Advanced Chassis Setup Hard Drive Installation The hard drives are mounted in drive carriers to simplify their installation and removal from the chassis. System power may remain on when removing carriers with drives installed. These carriers also help promote proper airfl ow for the drive bays.
  • Page 84: Hard Drive Backplane

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Installing/Removing a Hard Drive 1. To remove a carrier, push the release button located beside the drive LEDs. 2. Swing the colored handle fully out and use it to pull the unit straight out (see Figure 6-4).
  • Page 85: Dvd-Rom Drive Installation

    Chapter 6: Advanced Chassis Setup DVD-ROM Drive Installation The top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay. The 6016T-6RFT+/6016T-6RF+ accomodates only slim DVD-ROM drives. Side mounting brackets are needed to mount a slim DVD-ROM drive in the 6016T- 6RFT+/6016T-6RF+ server.
  • Page 86: Power Supply

    The PWR Fail LED will illuminate and remain on until the failed unit has been replaced. Replacement units can be ordered directly from Supermicro (part number PWS-703-P-1R). The power supply units have a hot-swap capability, meaning you can replace the failed unit without powering down the system.
  • Page 87 Chapter 6: Advanced Chassis Setup Figure 6-5. Removing/Replacing the Power Supply...
  • Page 88 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Notes 6-10...
  • Page 89: Chapter 7 Bios

    When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note: the AMI BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text messages.) The AMI BIOS Setup Utility uses a key-based navigation system called "hot keys".
  • Page 90: Starting The Setup Utility

    Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential dam- ages arising from a BIOS update. If you have to update the BIOS, do not shut down or reset the system while the BIOS is updating.
  • Page 91 <Enter>. Press the <Tab> key to move between fi elds. The date must be entered in Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.) SuperMicro X8DTU-6TF+ • Version: This item displays the BIOS revision used in your system.
  • Page 92: Advanced Setup Confi Gurations

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Advanced Setup Confi gurations Use the arrow keys to select Advanced and press <Enter> to access the submenu items. Boot Features Quick Boot If enabled, this feature will skip certain tests during POST to reduce the time needed for system boot.
  • Page 93: Processor And Clock Options

    Chapter 7: BIOS Hit 'Del' Message Display Select Enabled to display "Press DEL to run Setup" during POST. The options are Enabled and Disabled. Interrupt 19 Capture Interrupt 19 is the software interrupt that handles boot disk functions. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture"...
  • Page 94 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual • Cache L2: This item displays the size of Cache L2 of the CPU for the moth- erboard. • Cache L3: This item displays the size of Cache L3 of the CPU for the moth- erboard.
  • Page 95 Chapter 7: BIOS Intel® Virtualization Technology (Available when supported by the CPU) Select Enabled to use the feature of Virtualization Technology to allow one platform to run multiple operating systems and applications in independent partitions, creat- ing multiple "virtual" systems in one physical computer. The options are Enabled and Disabled.
  • Page 96: Advanced Chipset Control

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual C1E Support Select Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces the CPU's power consumption by reducing the CPU's clock cycle and voltage during a "Halt State". The options are Disabled and Enabled. Intel®...
  • Page 97 Chapter 7: BIOS • Memory Reference Code: This item displays the memory reference code for the motherboard. • QPI Reference Code: This item displays the QPI reference code for the moth- erboard. QPI (Quick Path Interconnect) Links Speed QuickPath Interconnect (QPI) is the connection between the CPU and the motherboard's I/O hub.
  • Page 98 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Channel Interleave This feature allows the user to confi gure the Memory Interleave settings for an onboard memory channel. The options are 1-way, 2-way, 3-way, 4-way, and 6-way. Bank Interleave This feature allows the user to confi gure the Memory Interleave settings for an onboard memory bank.
  • Page 99 Chapter 7: BIOS IOH PCI-E Max Payload Size Some add-on cards perform faster with the coalesce feature, which limits the payload size to 128B; while others, with a payload size of 256B which inhibits the coalesce feature. Please refer to your add-on card user guide for the desired setting. The options are 256B and 128B.
  • Page 100 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual SATA#1 Confi guration If Compatible is selected, it sets SATA#1 to legacy compatibility mode, while se- lecting Enhanced sets SATA#1 to native SATA mode. The options are Disabled, Compatible and Enhanced. Confi gure SATA#1 as (Not available when SATA#1 Confi guration is disabled) This feature allows the user to select the drive type for SATA#1.
  • Page 101 Chapter 7: BIOS LBA/Large Mode LBA (Logical Block Addressing) is a method of addressing data on a disk drive. In the LBA mode, the maximum drive capacity is 137 GB. For drive capacities over 137 GB, your system must be equipped with a 48-bit LBA mode addressing. If not, contact your manufacturer or install an ATA/133 IDE controller card that supports 48-bit LBA mode.
  • Page 102 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Select SWDMA2 to allow the BIOS to use Single Word DMA mode 2. It has a data transfer rate of 8.3 MB/s. Select MWDMA0 to allow the BIOS to use Multi Word DMA mode 0. It has a data transfer rate of 4.2 MB/s.
  • Page 103 Chapter 7: BIOS Plug & Play OS Selecting Yes allows the OS to confi gure Plug & Play devices. (This is not required for system boot if Plug & Play is supported by your OS.) Select No to allow the AMI BIOS to confi...
  • Page 104 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual  Super IO Device Confi guration Serial Port1 Address/ Serial Port2 Address This option specifi es the base I/O port address and the Interrupt Request address of Serial Port 1 and Serial Port 2. Select Disabled to prevent the serial port from accessing any system resources.
  • Page 105: Hardware Health Monitor

    Chapter 7: BIOS to keep Console Redirection active during POST and Boot Loader. The options are Disabled, Boot Loader, and Always. Terminal Type This feature allows the user to select the target terminal type for Console Redirec- tion. The options are ANSI, VT100, and VT-UTF8. VT-UTF8 Combo Key Support A terminal keyboard defi...
  • Page 106 ‘Temperature Tolerance’ is, and not the other way around. This results in better CPU thermal management. Supermicro has leveraged this feature by assigning a temperature status to certain thermal conditions in the processor (Low, Medium and High). This makes it easier for the user to understand the CPU’s temperature status, rather than by just simply...
  • Page 107 Chapter 7: BIOS 2. The information provided above is for your reference only. For more information on thermal management, please refer to Intel’s Web site at www.Intel.com. System Temperature: The system temperature will be displayed (in degrees in Celsius and Fahrenheit) as it is detected by the BIOS. Fan 1 ~ Fan 8 Reading This feature displays the fan speed readings from fan interfaces Fan 1 through Fan 8.
  • Page 108 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual ACPI APIC Support (Available ACPI Aware O/S='Yes') Select Enabled to include the ACPI APIC Table Pointer in the RSDT (Root System Description Table) pointer list. The options are Enabled and Disabled. APIC ACPI SCI IRQ When this item is set to Enabled, APIC ACPI SCI IRQ is supported by the system.
  • Page 109 Chapter 7: BIOS BIOS AC[SCLEAN] (Available when Intel TXT(LT) Initialization is enabled) Select Enabled to allow the processor to load an authenticated code (AC) module in an internal memory partition to ensure that the CPU, chipset and all other related components are launched in the same protected environment for trusted-platform computing.
  • Page 110: View Bmc System Event Log

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Execute TPM Command (Available when TCG/TPM Support = 'Yes') Select Enabled to execute TPM commands you've selected. Select Don't Change to keep the current TPM commands without making any changes. Select Dis- abled to abandon the changes you have made on TPM commands. The options are Enabled, Disabled and Don't Change.
  • Page 111 Chapter 7: BIOS • SEL Record Type • Event Timestamp • Generator ID • Event Message Format Ver. • Event Sensor Type • Event Sensor Number, • Event Dir Type • Event Data. Clear BMC System Event Log Clear BMC System Log now Select OK and press the <Enter>...
  • Page 112 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual assigned to the client can be reassigned to a new client. Select Static (Static Allocation) to allow the host server to allocate an IP address based on a table containing MAC Address/IP Address pairs that are manually entered (probably by a network administrator).
  • Page 113: Security Settings

    Chapter 7: BIOS after an operating system failure is detected. The options are [5 Min], [1 Min], [30 Sec], and [10 Sec]. DMI Event Log Confi guration View Event Log Use this option to view the System Event Log. Mark All Events as Read This option marks all events as read.
  • Page 114 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Supervisor Password This item indicates if a Supervisor password has been entered for the system. "Not Installed" means a Supervisor password has not been used. User Password This item indicates if a user password has been entered for the system. "Not In- stalled"...
  • Page 115: Boot Confi Guration

    Chapter 7: BIOS Boot Confi guration Use this feature to confi gure boot settings. Boot Device Priority This feature allows the user to specify the sequence of priority for the Boot Device. The settings are 1st boot device, 2nd boot device, 3rd boot device, 4th boot device, 5th boot device and Disabled.
  • Page 116: Exit Options

    UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Exit Options Select the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Save Changes and Exit When you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility and reboot the computer, so the new system con- fi...
  • Page 117 Chapter 7: BIOS Load Fail-Safe Defaults To set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Safe settings are designed for maximum system stability, but not for maximum performance. 7-29...
  • Page 118 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Notes 7-30...
  • Page 119: Appendix A Bios Error Beep Codes

    Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
  • Page 120 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Notes...
  • Page 121: Appendix B System Specifi Cations

    Appendix B: System Specifi cations Appendix B System Specifi cations Processors Single or dual Intel® 5500/5600 Series processors in LGA1366 sockets Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel 5520/ICH10R chipset BIOS 32 Mb AMI®...
  • Page 122 UPER ERVER 6016T-6RFT+/6016T-6RF+ User's Manual Expansion Slots Left side: two PCI-E x8 add-on cards (w/ RSC-R1UU-2E8 riser) Right side: one PCI-E x8 card (w/ RSC-R1UU-E8R+ riser) Serverboard 6016T-6RFT+: X8DTU-6TF+ (Proprietary form factor) 6016T-6RF+: X8DTU-6F+ (Proprietary form factor) Dimensions: 16.5 x 12.8 in (419 x 325 mm) Chassis SC819TQ-R700U (1U rackmount) Dimensions: (WxHxD) 19 x 1.7 x 27.75 in.
  • Page 123 Appendix B: System Specifi cations Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) California Best Management Practices Regulations for Perchlorate Materials:...
  • Page 124 Notes (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in signifi...

This manual is also suitable for:

Superserver 6016t-6rf+

Table of Contents