Installing The Chassis Rails; Installing The Rack Rails - Supero SUPERSERVER 6016T-T User Manual

Table of Contents

Advertisement

Installing the Chassis Rails

Position the fi xed chassis rail sections you just removed along the side of the
chassis making sure the fi ve screw holes line up. Note that these two rails are
left/right specifi c. Screw the rail securely to the side of the chassis (see Figure
2-2). Repeat this procedure for the other rail on the other side of the chassis.
You will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which
serves two functions. The fi rst is to lock the server into place when installed and
pushed fully into the rack, which is its normal position. Secondly, these tabs also
lock the server in place when fully extended from the rack. This prevents the
server from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails

Installing the Rack Rails

Determine where you want to place the 6016T-T in the rack (see Rack and Server
Precautions in Section 2-3). Position the fi xed rack rail/sliding rail guide assemblies
at the desired location in the rack, keeping the sliding rail guide facing the inside
of the rack. Screw the assembly securely to the rack using the brackets provided.
Attach the other assembly to the other side of the rack, making sure that both are
at the exact same height and with the rail guides facing inward.
Chapter 2: Server Installation
2-5

Advertisement

Table of Contents
loading

Table of Contents