F2880, F3680, RCK72-F36, RCK72R-F36, RCK60-F36, RCK60R-F36, WSM
Stopping the Engine, Automatically
(1) Battery
(2) Starter
(3) Slow Blow Fuse (50A)
(4) Main Switch
(5) Fuse (5A)
When the following conditions become complete, the electrical current does not flow to the holding coil (14) of the
engine stop solenoid (13) from the controller (11). Then, the engine will stop in 0.6 to 1.4 seconds.
Condition
1
2
3
(6) Glow Plug
(7) Glow Plug Lamp
(8) Seat Switch
(9) PTO Switch
(10) Brake Switch
Seat Switch (8)
(Occupied : ON)
(Vacant : OFF)
OFF
OFF
OFF
(11) Controller
(12) Frame Earth
(13) Engine Stop Solenoid
(14) Holding Coil
(15) Pulling-in Coil
PTO Switch (9)
(Disengaged : ON)
(Engaged : OFF)
ON
OFF
OFF
8-M6
ELECTRICAL SYSTEM
[A] Condition 1
[B] Condition 2
[C] Condition 3
Brake Switch (10)
(Pedal depressed : ON)
(Pedal free : OFF)
OFF
ON
OFF
KiSC issued 04, 2006 A
W1015064