4.3.2 Rate Control
This page provides rate control on each port - it contains Ingress and Egress items and the unit is 128Kbps. The rate control
screen is displayed as in
Figure 4-3-2.
The page includes the following fields:
Object
Rate Control:
(Unit: 128KBbps)
Port
Ingress
Egress
Figure 4-3-2: Rate Control Interface Screenshot
Description
Port-1 ~ Port-10, supports by-port ingress and egress rate control.
For example, assume port 1 is 10Mbps, users can set its effective egress rate at
1Mbps and ingress rate at 500Kbps. Device will perform flow control or
backpressure to confine the ingress rate to meet the specified rate.
Allows user to choose which port will be limited rate speed.
Type the port effective ingress rate.
The valid range is
8000. The unit is 128K.
0 ~
0: disable rate control.
1 ~ 8000: valid rate value
Type the port effective egress rate.
The valid range is
8000. The unit is 128K.
0 ~
0: disable rate control.
1 ~8000: valid rate value.
63
User's Manual of FGSD-1022 Series