The page includes the following fields:
Object
PoE PSU Status
PoE Temperature Unit 1
PoE Temperature Unit 2
Temperature Threshold
Over Temperature Protection
Power limit mode
PoE Usage Threshold
Power Allocation
PoE Function
PoE Schedule
Priority
Device class
Current(mA)
Description
PoE PSU Status shows status of power supply for PoE output.
Display the current operating temperature of PoE chip unit 1.
The unit 1 is in charge of PoE Port-1~Port-4
Display the current operating temperature of PoE chip unit 2.
The unit 1 is in charge of PoE Port-5~Port-8
Allows user to set temperature threshold manually. System will issue alert
message to system log and syslog if PoE unit temperature over the threshold.
Enable / Disable over temperature protection.
When the PoE temperature unit 1 / unit2 over 70 degree C then PoE power
budget will be changed by 3 segments as following:
Over 70 Degree C power budget 180 Watts
Over 73 Degree C power budget 170 Watts
Over 76 Degree C power budget 160 Watts
Allow to configure power limit mode of Web Smart Device. It can choose :
Total Limit mode : Customize power to PoE port
Classification mode : Reserve power to PD by PoE class level
Consumption mode : Deliver power to PD by real power consumption
Allows user to set the threshold value for issues alert message if PoE power
usage over the vaule.
Show currently total PoE power budget.
Can enable or disable the PoE function.
Allows user to set PoE schedule profile to offer PoE power according to time
table.
Set port priority for the POE power management
It can choose the "port priority", value is :
 Critical
 High
 Low
High priority is "Critical".
Class 0 is the default for PDs. However, to improve power management at the
PSE, the PD may opt to provide a signature for Class 1 to 3.
The PD is classified based on power. The classification of the PD is the
maximum power that the PD will draw across all input voltages and operational
modes. A PD shall return Class 0 to 3 in accordance with the maximum power
draw as specified by Table 4-13-1.
It shows the PoE device current Amp.