General Network
Connection
Problems
Symptom
Possible Cause
Remote network is
LAN or WAN
not responding (e.g.
connection problem.
to PINGs or the Web
browser connection
requests.)
Incorrect Virtual Circuit
(VC) information has
been entered. Use the
Monitor > ATM screen
to observe ATM error
counts. If the BadVPI or
VDI error count is
incrementing, the
problem may be an
incorrect VC identifier.
Network Service (RFC
1483 or PPP) on
OfficeConnect Remote
840 is incompatible
with that used on
remote site ATM
router.
The remote site profile
may not be enabled.
Check the Monitor>
Remote Sites > Remote
Sites Configured to see
if the remote site status
is ENABLED.
General Network Connection Problems
Correction Action
1 See
"LAN Connection
Problems"
Connection
2 Go to Monitor > Networks >
Network Status to view more
detailed problem, then take
corrective action.
Check the VC information and
correct as needed.
RFC 1483 and PPP network service
run above ATM. If you select PPP
and RFC 1483 is running on the
remote site router, you will not be
able to successfully access the
remote network. Change the
network service to agree with the
remote router network service.
Enable the remote site profile.
13-7
and
"WAN
Problems".