1. Press"*" key on the keypad and input 8 digits ARM password, then press "#" key to arm/disarm
the system.
2. If the system is in disarmed mode (the yellow LED is OFF), press"#" to arm the system. The
system will enter the arm delay period (the yellow LED will slowly flash).
If the system is in armed mode (the yellow LED is ON) or in the arm delay period (the yellow LED
is flashing slowly), press "#" to disarm the system. Then the system will enter the disarmed
mode (the yellow LED will be off).
3. In any system mode, press "*" to exit the arm operation. If no key is pressed for 20 seconds, the
reader will automatically log out of the arm operation mode.
5.12.5 Arm/Disarm the Systemusing aLCDReader
New model of readers, ERL‐871 in EverAccess series was released to provide a more intuitive user
interface to interact with the system. ERL‐871 provides a large LCD to show more information from
controller.
The steps to arm/disarm system with ERL‐871 are explained below:
1. Press "*" on keypad, input 8 digits ARM password and press "#" to confirm.
2. After entered the ARM menu, press "#" key to arm/disarm the system. Press "*" to exit the
system.
5.13 Use Reader as Keypad
Access control system provides a keypad to control a door and approve or deny an access request. NAV
Controller provides the same function with the correct setting.
To use PIN only to access a door, set the door verification mode as "Card or PIN or fingerprint", and set
the keypad reader with the enabled keypad property. When these setting are all configured right, users
can key in the valid card PIN at the keypad reader and press # to gain the access. If the PIN matches the
records in the system and the door verification mode allows, the controller will unlock the door.
Take the operation on ERL871 LCD keypad reader as example, the steps to use PIN only to access are
listed below:
1. Press any numeric key on ERL871 keypad, the below screen will show and the first inputted key
will be stored there already:
2009-02-01
09:38
Input Password:
________
2009-02-01
09:38
System disarmed
[ENT] to toggle
60
NAV IP Access controller