NAV IP Access controller
System will display the current delay time as shown below. Use numeric keys to input the desired ARM 
delay time. Enter minutes as a 3‐digit number 0~999 and seconds as a 2‐digit number 0~59. The default 
value of ARM delay time is 30 seconds.  
Press 
 to confirm. Press 
 
5.6.4.19
Alarm Out Time Setting
As described in alarm input mode, alarm timeout defines the duration of alarm output being presented 
(alarm  relay  energized),  when  triggered  by  the  specified  alarm  input  and  if  the  alarm  output  mode  is 
configured  as  "Latched"  mode.  After  the  alarm  timeout  duration,  the  alarm  output  will  be  reset  to 
normal. The default alarm timeout duration is 60 seconds. 
Note fire alarm has to be manually reset. It does not limited by the alarm timeout duration. 
5.9.6 ALarm Event Setting 
The physical alarm inputs can trigger alarm outputs. As described in previous section, the logic events, 
for  example,  unknown  card,  invalid  card,  expired  card,  invalid  door  and  etc.,  can  trigger  the  alarm 
outputs as well. 
Press 
 at the below window to configure the event alarm setting. 
Two  submenus  are  included  in  event  alarm  setting:  event  alarm  time  setting  and  event  alarm  action 
setting, explained in the following sections. The screens of the two settings are shown below: 
5.6.4.20
Event Alarm Time Setting
Press 
 at  the  screen  of  "Event  Alarm  Time  Setting"  to  configure  event  alarm  time  setting.  As 
introduced earlier, NAV Controller allows a logical event to trigger an alarm output. The duration of the 
alarm output can be specified per event type. Different event types can generate the different duration 
of the alarm output. The default value of event alarm time is 1 minute. 
The  following  windows  show  the  event  alarm  time  setting  on  different  events.  All  events  will  be 
explained one by one. 
SYS PIN Fail 
Arm Delay Time
000Min 30Sec
 to exit without effecting any change. 
alarm time
001Min 00Sec
 
Event Alarm Setting
EventAlarm time
Setting
EventAlarm action
Setting
 
 