NAV IP Access controller
System will display the current delay time as shown below. Use numeric keys to input the desired ARM
delay time. Enter minutes as a 3‐digit number 0~999 and seconds as a 2‐digit number 0~59. The default
value of ARM delay time is 30 seconds.
Press
to confirm. Press
5.6.4.19
Alarm Out Time Setting
As described in alarm input mode, alarm timeout defines the duration of alarm output being presented
(alarm relay energized), when triggered by the specified alarm input and if the alarm output mode is
configured as "Latched" mode. After the alarm timeout duration, the alarm output will be reset to
normal. The default alarm timeout duration is 60 seconds.
Note fire alarm has to be manually reset. It does not limited by the alarm timeout duration.
5.9.6 ALarm Event Setting
The physical alarm inputs can trigger alarm outputs. As described in previous section, the logic events,
for example, unknown card, invalid card, expired card, invalid door and etc., can trigger the alarm
outputs as well.
Press
at the below window to configure the event alarm setting.
Two submenus are included in event alarm setting: event alarm time setting and event alarm action
setting, explained in the following sections. The screens of the two settings are shown below:
5.6.4.20
Event Alarm Time Setting
Press
at the screen of "Event Alarm Time Setting" to configure event alarm time setting. As
introduced earlier, NAV Controller allows a logical event to trigger an alarm output. The duration of the
alarm output can be specified per event type. Different event types can generate the different duration
of the alarm output. The default value of event alarm time is 1 minute.
The following windows show the event alarm time setting on different events. All events will be
explained one by one.
SYS PIN Fail
Arm Delay Time
000Min 30Sec
to exit without effecting any change.
alarm time
001Min 00Sec
Event Alarm Setting
EventAlarm time
Setting
EventAlarm action
Setting