Door module
Each door module can provide +12V voltage for two readers. Twisted cable is
recommended to connect the controller and readers. The maximum transmission
distance between the reader and controller depends on the gauge of the cable and the
specification of the reader. Please read the reader user manual carefully before installing
the cable for the readers.
Note: It is strongly recommended to use one connection format in a multi‐reader system,
i.e. all the readers are connected to the door modules through RS‐232 or Wiegand
connection. Multiple connection formats could cause compatibility problems to the
system.
2.2.3 Connecting to the Door Lock, Sensor and Open Button
Connecting to the Door Lock
The Electric strikes and magnetic locks are used to keep doors locked unless the system
grants access or the user sets the doors to remain unlocked. One strike or magnetic lock
is required for each door. These locks must be powered separately from the readers. The
mounting instructions for strikes and magnetic locks vary depending on the
manufacturer and type of lock. Please consult the instructions included with the door
hardware when installing. Once the locks are installed, follow the instructions below to
connect them to the controller.
Electric Strike
Connect the wires from the electric strike to the terminal block on the door module.
You can either connect the wires to Pin 11 and 12 (Door 1) or Pin 27 and 28 (Door 2)
on the terminal block.