NAV IP Access controller
Press 
 to enter Over Time setting. Use 
Input the desired door hold open time in the Open Time field: enter minutes as a 3‐digit number 0~999, 
and enter seconds as a 2‐digit number 0~59. Press 
any change. 
 
5.8 Reader Setting 
Card  reader  properties  can  be  directly  set  on  the  controller,  including  whether  the  reader  is  keypad 
reader, the allocation of readers to doors, and system reader etc. 
5.8.1 Enter Reader Setting Menu 
Under System menu, press 
Press 
 to enter Reader Setting menu. Use 
All menu options under Reader Setting are introduced below:
5.8.2 System Reader Setting 
System reader can be used to acquire the card's serial number when controller configures the card. User 
can set any reader that connects to the controller as the system reader. At the following submenu: 
Press 
 to  enter  System  Reader  setting.  System  will  show  current  status  of  all  readers  as  shown 
below.  Y  means  the  reader  is  the  system  reader,  N  means  it's  not.  By  default,  no  reader  is  set  as  the 
system reader. Users have to set it manually. 
Press any of the 1‐8 numeric keys to change the system reader setting of corresponding readers. Press 
 to exit. 
 
5.8.3 Keypad Setting 
Keypad Setting defines whether the reader is a keypad reader. For a keypad reader, if the PIN property 
of the card is set as enabled, and the access rights of the door are set as card plus PIN, then the user is 
asked to enter password when the card is swiped on the keypad reader. At the following submenu: 
Press 
to  enter  keypad  setting.  System  will  show  keypad  setting  status  of  all  installed  readers.  Y 
means the reader is a keypad reader, and N means the reader is a non‐keypad reader. By default, every 
Door-1Over Time
000Min 05 Sec
 to confirm. Press 
 twice to bring up the following window: 
Reader Setting
and 
System Reader
Setting
12345678
NNNNNNNN
Keypad Setting
 
43
 and 
to choose from different door.  
 
 to exit without effecting 
 to choose from different menu options. 
 