reader is set as a non‐keypad reader. Flex controller will display the door number according to the
number of installed door modules. In the following example, 4 door modules (8 readers) have been
installed on the controller.
Press numeric keys to toggle the keypad setting of corresponding reader. Press
to exit without effecting any change.
5.8.4 Reader to Door Allocation
NAV Controller can be flexibly configured. Readers can be allocated to different doors, and can be set as
ENTER only or EXIT only. By default, each reader is allocated as ENTER only to the door with the reader's
number. At the following submenu:
Press
to enter Reader to Door Allocation setting. System will show the allocation of the first reader
to door as following:
Press any of the 1‐8 numeric keys to allocate the current reader to corresponding doors. (This depends
on the actual door modules installed on the controller) Press the same numeric key to toggle between
ENTER only (IN) and EXIT only (OUT).
Press the
or
to select the different readers. Press
5.8.5 Reader Backlight Setting
At the following submenu:
Press
to enter Reader Backlight Setting. As shown below, the system will show if the backlight
setting of all readers are turned on or off. Y indicates ON, N indicates OFF. The default setting of
backlight is OFF. Note this feature only applies the reader released after Q3, 2010.
Press any of the 1‐8 numeric keys to change the backlight setting of each reader. Press
5.8.6 Set Reader LED or LCD format
At the following submenu:
12345678
NNNNNNNN
Reader to Door
Allocation
Reader-1
Door-1-IN
Reader Backlight
Setting
12345678
NNNNNNNN
44
NAV IP Access controller
to confirm. Press
to exit.
to exit.