Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)
HDX type of Fast Ethernet devices).
There are three LED's per fiber port. The Link (LK) LED indicates "ready for
operation" on that port when lit, the F/H LED indicates operation in full-duplex mode
when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving
Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK)
indicator for that port must be ON (indicating there is a powered-up device at the other
end of the cable) in order for a LK LED to provide valid indications of operating
conditions on that port.
2.2.3

Eight-Port Copper Module, 6K8-RJ45

The 6K8-Series's 8-port Copper port module, model 6K8-RJ45, provides eight
10/100Mb switched RJ-45 ports. The 10/100Mb switched ports normally (as a default
setting) are independently N-way auto-negotiating, and auto-crossover(MDIX) for
operation at 10 or 100Mb speed in full- or half-duplex mode, i.e., each independently
selects a mode and speed to match the device at the other end of the twisted pair cable.
(See Section 4.3 for auto-negotiation and MDIX details). The auto-crossover feature will
automatically determine the other side of connection to make the connection, and
eliminate the need of cross-over cable.
On the model 6K8-RJ45 module, there are four LEDs for each port, two in the
connector and two separate. The LK (Link) LED indicates "ready for operation" on that
port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port
when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb
speed when OFF (when auto-
negotiation is not disabled).
The FDX/HDX LED is ON
to indicate full-duplex
operation and OFF to indicate
half-duplex mode. A twisted
pair cable must be connected
into an RJ-45 port and the Link (LK) indicator for that port must be ON (indicating there
is a powered-up device at the other end of the cable) in order for a LK LED to provide
valid indications of operating conditions on that port.
Using the 6K16-Series (MNS-6K) management software, the user may disable
auto-negotiation and fix the desired operation of each RJ-45 port. User may select 10Mb
www GarrettCom com
.
.
1
10/100
F/ H
2
10/100
F/H
14
3
5
7
4
6
LK
ACT
8
LK
ACT