Local Area Network (Lan) Interface Mode - SATO GL4xxe Series Operator's Manual

Gl4e series
Hide thumbs Also See for GL4xxe Series:
Table of Contents

Advertisement

UNIVERSAL SERIAL BUS (USB) INTERFACE MODE (TABLE 4-7)
MENU
Comm. Protocol
Status 5*
INTERFACES
Host Interface
Host Interface
USB*
USB Port
Buffer Size in K
Buffer Size in K
1 to 16KB*
Timeout
10 sec*
LOCAL AREA NETWORK (LAN) INTERFACE MODE (TABLE 4-8)
MENU
INTERFACES
GL408-412e Operator's Manual
Unit 4: Printer Configuration
Communication Protocol. Selects the mode of Bi-Directional communications. In most cases this
menu does not need to be altered and is meant to help support legacy applications which may
have incorporated older bi-directional statuses. Anything other than Staus 5 or Standard (none) is
not recommended.
• Status 5 - factory default. Most advanced of the options. This status is the most recent and
represented in the interface specifications. For more information, refer to the appropriate
section in the programming and interface guide.
• Standard - bi-directional interface is not used.
• Status 2 - legacy bi-directional support. Not recommended for new applications.
• Status 3 - legacy bi-directional support. Not recommended for new applications.
• Status 4 - legacy bi-directional support. Not recommended for new applications.
Is the menu selection screen for the USB Port option of the INTERFACES mode.
Is the main menu screen for the Host Interface option of the INTERFACES mode. There are only
two options relative to the serial interface, ignore all others.
• Auto Switching - the printer automatically switches to the relative interface type and moves
into the applicable menus.
• USB - factory default. Allows the operator to select the interface and the relative menus will
follow.
Is a transitional screen that will allow the buffer size to be established in the following screen.
This menu configures the amount of memory allocated for the serial port buffer. The range is 1 to
16 Kbytes in 1 kbyte increments.
Note: If a baud rate 19200 or greater is selected, the Buffer Size in K parameter may need to be
increased from the default to 16 Kbytes to improve performance.
The factory default is 16.
This is the value used by the printer to time out from the current port and check the other selected
Port Types for data print. When the printer has not received data from the host after a certain
period of time, it must timeout in order to service other ports.
The factory default of 10 seconds with an allowable range of 1 to 60 seconds.
Permits entry into the INTERFACES Mode.
DESCRIPTION
DESCRIPTION
4-52

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gl412eGl408eGl408

Table of Contents