Technical Specifications; Power Supply Specifications; Failsafe Relay Specifications - RuggedCom RS900L Installation Manual

Ethernet switch
Hide thumbs Also See for RS900L:
Table of Contents

Advertisement

RUGGEDCOM RS900L
Installation Guide

Technical Specifications

The following sections provide important technical specifications related to the device and available modules:
Section 4.1, "Power Supply Specifications"
Section 4.2, "Failsafe Relay Specifications"
Section 4.3, "Copper Ethernet Port Specifications"
Section 4.4, "Fiber Optic Ethernet Port Specifications"
Section 4.5, "Operating Environment"
Section 4.6, "Mechanical Specifications"
Section 4.1

Power Supply Specifications

Power Supply Type
HI
24
48
a
(F) denotes fast-acting fuse
b
(T) denotes time-delay fuse.
c
Power consumption varies based on configuration.
Section 4.2

Failsafe Relay Specifications

Rated Switching Current
d
Dielectric test voltage (1 minute) between coil and contacts
Power Supply Specifications
Input Range
Minimum
88 VDC
85 VAC
10 VDC
36 VDC
Parameter
Max Switching Voltage
Isolation
Internal Fuse
Rating
Maximum
300 VDC
264 VAC
3.15 A(T)
36 VDC
72 VDC
Isolation
ab
4 kVAC
5.5 kVDC
1.5 kVDC
1.5 kVDC
Value (Resistive Load)
30 VAC, 80 VDC
0.3 A @ 30 VAC
1 A @ 30 VDC, 0.3 A @ 80 VDC
d
1500 V
rms
Chapter 4
Technical Specifications
Maximum Power
c
Consumption
10 W
19