Removing the Bail Sensor

1 Remove the electronics enclosure
cover D page 6 5.
2 Remove the window D page 6 15.
3 Remove the center cover D page 6 16.
4 Remove the right endcover D page 6 19.
Bail sensor
6 Disconnect the bail sensor cable
connector from the main PCA, and from
its ferrite and holding clip on the right
sideplate.
The ferrite holder opens from the top.
Bail-sensor
connector
Reassembling: The cable goes through
the same ferrite as for the window sensor
cable D page 6 24.
7 Carefully feed the bail sensor cable out
from the electronics enclosure and from
under the motor assemblies.
C3187 90000
5 Note the position of the bail sensor cable
for reassembly. Incorrect positioning
could cause obstruction of the cartridge
carriage and motor gears.
8 Unclip the bail sensor from its holder,
and lift it, with cable, clear of the plotter.
Bail-sensor
holder
Bail sensor
Calibration: After having
reassembled the plotter, perform
the bail calibration D chapter 7.
Removal and Replacement
6 55