PLEASE NOTE CLEARANCES BELOW:
Minimum clearances from COMBUSTIBLE CONSTRUCTION are:
TYPE
ALL MODELS
WALL MOUNTED UNITS
The Minimum clearances from NON-COMBUSTIBLE CONSTRUCTION are:
TYPE
ALL MODELS
WALL MOUNTED UNITS
NOTE: No additional clearance from the sides and rear is required for service, as the units are serviceable from the
front.
THESE PROCEDURES MUST BE FOLLOWED BY QUALIFIED PERSONNEL OR WARRANTY
WILL BE VOIDED.
FOR AN APPLIANCE EQUIPPED WITH CASTERS, THE INSTALLATION SHALL BE MADE
WITH A CONNECTOR THAT COMPLIES WITH THE STANDARD FOR CONNECTORS FOR
MOVABLE GAS APPLIANCES, ANSI Z21.69-LATEST EDITION, CAN1 6.10.88, AND A QUICK-
DISCONNECT DEVICE THAT COMPLIES WITH THE STANDARD FOR QUICK-DISCONNECT
DEVICES FOR USE WITH GAS FUEL, ANSI Z21.41-LATEST EDITION AND CAN1 6.9 M79.
ADEQUATE MEANS MUST BE PROVIDED TO LIMIT THE MOVEMENT OF THE APPLIANCE
WITHOUT DEPENDING ON THE CONNECTOR AND THE QUICK-DISCONNECT DEVICE OR
ITS ASSOCIATED PIPING TO LIMIT THE APPLIANCE MOVEMENT.
IF DISCONNECTION OF THIS RESTRAINT IS NECESSARY TO MOVE THE APPLIANCE FOR
CLEANING, ETC., RECONNECT IT WHEN THE APPLIANCE IS MOVED TO ITS
ORIGINALLY INSTALLED POSITION.
NOTE: Adequate restraining means must be attached to rear of appliance when installed. Installation must conform to
local codes as applicable.
ASSEMBLY INSTRUCTIONS FOR MODEL 3230A SALAMANDER:
The Model 3230A can be mounted to a Sectional Series Range or be mounted to a wall (3230AW).
A. 3230A Mounted to a Sectional Range.
The 3230A is completely assembled at the factory to the flue riser of the specified sectional range as ordered. The
flue riser may or may not be mounted to the sectional range. If it is not proceed as follows:
1. Front panel "A" is fastened with six (6) sheet metal screws. Remove the screws and the panel will come
loose. (See Fig. 1.)
2. Remove the nuts and lockwashers from collar plate studs "C" on unit.
3. Lower the flue riser with the 3230A mounted on it onto the unit such that studs "C" enter the holes in the
shelf bracket. Be certain to adequately support the broiler. Secure shelf bracket "B" with the nuts and
lockwashers which were removed previously.
4. The flue riser extension "D" is packed with the unit. Slide extension over the flue "E" protruding through the
center opening of the collar plate T."
INSTALLATION
SIDES
6 IN.
6 IN.
SIDES
0 IN.
0 IN.
WARNING:
WARNING:
WARNING:
REAR
6 IN.
0 IN.
REAR
0 IN.
0 IN.
SALAMANDER RADIANT BROILER
SECTION ONE — INSTALLATION
PAGE 3

Hide quick links:

Advertisement

loading

This manual is also suitable for: