Download Print this page

Advertisement

Quick Links

Owner's Manual
Radiant Broilers
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury
or death. Read the installation, operating and maintenance instructions thoroughly before installing or
M
R
ANUAL 1199797
EV 0 (6/14)
$21.00
234R
servicing this equipment.
1100 Old Honeycutt Road Fuquay-Varina, North Carolina 27526 USA
www.southbendnc.com
P32D-3240
WARNING
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this
manual for the life of the equipment:
Model #: ___________________________
Serial #: ___________________________
Date Purchased: _____________________
RADIANT BROILER
MANUAL SECTION BR

Advertisement

loading

Summary of Contents for Southbend 234R

  • Page 1 Serial #: ___________________________ Date Purchased: _____________________ Owner’s Manual Radiant Broilers P32D-3240 234R WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
  • Page 2 Southbend replacement parts are installed. Give this Owner’s Manual and important papers to the proper authority to retain for future reference. Copyright © 2014 by Southbend. All rights reserved. Published in the United States of America. PAGE 2 OF 40...
  • Page 3: Table Of Contents

    Congratulations! You have purchased one of the finest pieces of heavy-duty commercial cooking equipment on the market. You will find that your new equipment, like all Southbend equipment, has been designed and manufactured to meet the toughest standards in the industry. Each piece of Southbend equipment is carefully engineered and designs are verified through laboratory tests and field installations.
  • Page 4 NTRODUCTION ADIANT ROILER The serial plate is located on the interior side of the lower front panel, as shown below. Figure 1 Broiler Serial Plate Location The serial plate is located behind the access panel. To remove the panel, lift it straight up and pull it out at the bottom. Figure 2 Oven Serial Plate Locations Location of Serial Plate...
  • Page 5: Specifications

    Therefore, installations should comply with all local codes. Southbend reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, additions, or replacements for previously purchased equipment.
  • Page 6 PECIFICATIONS ADIANT ROILER NOTICE Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the warranty. Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s instructions. If a ventilation canopy is used, it is recommended that the canopy extend 152.4 mm (6”), past the appliance and that the bottom edge be located 1981 mm (6’6”) from the floor.
  • Page 7 (see Figure 1 and Figure 2). Connect the Southbend cooking equipment ONLY to the type of gas for which it is configured and adjusted.
  • Page 8 PECIFICATIONS ADIANT ROILER Figure 3 Free Standing Broiler Preasure Tap Location 1/8" NPT Pressure Tap Figure 4 Oven Base Broilers Pressure Tap Locations 1/8" NPT PRESSURE TAP 1/8" NPT PRESSURE TAP PAGE 8 OF 40 OWNER’S MANUAL 1199797 REV 0 (6/14)
  • Page 9: Installation

    35 mbar (14” W.C). NOTICE EXHAUST FANS AND CANOPIES: It is recommended that the Southbend equipment be installed under a ventilation hood. Consult local codes for proper installation of hoods. Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by warranty.
  • Page 10 NSTALLATION ADIANT ROILER TTACH A set of four legs is packed with equipment ordered with legs. (For units ordered with casters, go to Step 2b.) Raise equipment sufficiently to allow legs to be attached. For safety, “shore up” and support the equipment with an adequate blocking arrangement strong enough to support the load.
  • Page 11 ADIANT ROILER NSTALLATION Figure 6 Installation of Casters TTACH ESTRAINT NOTICE For an appliance equipped with casters, (1) the installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances, CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect Devices for Use with Gas Fuel, CAN1-6.9, (2) adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick-...
  • Page 12 NSTALLATION ADIANT ROILER Figure 7 Installation of Restraint Be sure all controls are turned off prior to disconnecting. After reconnecting, be sure all controls are turned off and all pilots are lit. NOTICE Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit the appliance movement.
  • Page 13 ONNECT UPPLY If the Southbend equipment is being installed at over 2,000 feet altitude and that information was not specified when ordered, contact the appropriate authorized Southbend Service Representative or the Southbend Service Department. Failure to install with proper orifice sizing will result in poor performance and may void the warranty.
  • Page 14 NSTALLATION ADIANT ROILER If applicable, the vent line from the gas pressure regulator shall be installed to the outdoors in accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.
  • Page 15: Operation

    Children should be supervised to ensure that they do not play with the appliance. NOTICE Southbend Infrared broilers cook food in about half the time of conventional broilers, so adjust cooking times accordingly. IGHTING...
  • Page 16 PERATION ADIANT ROILER 5. When done broiling, turn the burner control knobs OFF (the constant-burning pilots will remain lit). 6. When done broiling, turn the burner controls to OFF. (To keep the broiler rack hot in order to mark food with sear marks without preheating, turn the burner controls to LOW and move the broiler rack to its highest position.) LIGHTING BROILER PILOTS The pilots should burn continuously unless the broiler is to be completely shut down.
  • Page 17 ADIANT ROILER PERATION Figure 8 Controls 3" Front 3" of broiler is a reduced-heat Upper Broiler holding area. Burner Controls (OFF-HIGH-LOW) Upper Broiler Rack (rolls out) Upper Broiler Rack Height Broiler Drippings Adjustment Lever Collection Drawer for Upper Broiler Lower Broiler Burner Controls (OFF-HIGH-LOW) Lower Broiler Rack...
  • Page 18 PERATION ADIANT ROILER Figure 9 Operation of Oven Each oven has a thermostatic control that can be set in the FOR UNITS WITH ELECTRONIC IGNITION oven 175°F to 550°F (66°C to 260°C). Convection ovens have a 1. Set the Oven Power Switch to ON. The pilot will light fan that can be set to HI speed or LO speed.
  • Page 19 ADIANT ROILER PERATION UGGESTIONS FOR OOKING SING A ONVECTION As a guide, set oven temperatures 25 to 50 degrees lower than called for in recipes using conventional (non-convection) ovens. FROZEN ENTREE PRODUCTS: Punch holes in lid before heating. Tent lid if product has a tendency to stick, i.e., lasagna or macaroni and cheese.
  • Page 20 If other appliances connected to the same source of gas or electricity are also not operating correctly, the problem is likely not within the equipment. If the problem only occurs for the Southbend equipment, and if the above solutions to do not solve the problem, call for repair service.
  • Page 21: Cleaning

    Southbend appliances are sturdily constructed of the best materials and are designed to provide durable service when treated with ordinary care. To expect the best performance, your equipment must be maintained in good condition and cleaned daily.
  • Page 22 Reserve procedure to reasemble broiling rack mechansim. NTERIOR WARNING FOR YOUR SAFETY, DISCONNECT THE POWER SUPPLY TO THE SOUTHBEND EQUIPMENT BEFORE CLEANING THE OVEN. WHEN CLEANING THE BLOWER WHEEL OF A CONVECTION OVEN, BE SURE TO HAVE THE POWER SWITCH IN THE “OFF” POSITION.
  • Page 23: Adjustments

    NOTICE Warranty will be void and the manufacturer is relieved of all liability if service work is performed by other than a qualified technician, or if other than genuine Southbend replacement parts are installed. ACCESS TO SERVICEABLE COMPONENTS To open the kick panel below the oven door, lift the kick panel straight up and pull the top edge away from the oven. The kick panel is hinged at the bottom corners.
  • Page 24 DJUSTMENTS ADIANT ROILER Figure 10 DJUSTMENT OF HERMOSTAT The oven thermostat is carefully calibrated at the factory so that the dial setting matches the actual oven temperature. Field recalibration is seldom necessary, and should not be resorted to unless considerable cooking experience definitely proves that the control is not maintaining the temperatures to which the dial is set.
  • Page 25 ADIANT ROILER DJUSTMENTS Figure 11 DJUSTMENT OF ILOT AND URNER The burner orifice is of the fixed type, sized for the type of gas and the operating altitude. To adjust the burner air-gas mixture, loosen the screw that secures the air shutter on the mixer face and rotate the mixer cap to obtain a clear, stable blue flame with a distinct inner cone at each port.
  • Page 26 RESSURE ( ASE) There is not an internal pressure regulator. The external pressure regulators supplied by Southbend are factory set at 6” W.C. for natural gas and 10” W.C. for propane gas. To check the manifold pressure, do the following: 1.
  • Page 27: Troubleshooting

    Warranty will be void and the manufacturer is relieved of all liability if service work is performed by other than a qualified technician, or if other than genuine Southbend replacement parts are installed. Replacement parts (including parts not listed in this manual) may be ordered either through a Southbend Authorized Parts Distributor or a Southbend Authorized Service Agency.
  • Page 28 ROUBLESHOOTING ADIANT ROILER ROUBLESHOOTING ROILER The following table lists the possible causes of oven-related problems that may occur Problem Look for - 1 Not enough heat – Restriction in valve. – Restriction in gas supply. – Misalignment of orifice tube. –...
  • Page 29 ADIANT ROILER ROUBLESHOOTING ROUBLESHOOTING CAUTION Proper and efficient operation of oven is dependent on correct installation and function of components. Always verify that components are in place and functioning as intended. The following table lists the possible causes of oven-related problems that may occur Problem Look for - 1 Oven will not come on.
  • Page 30 Value. If you continue to have if you continue to have issues after replacing the thermpile, then issues after replacing the safety valve, then contact Southbend contact Southbend Technical Support for assistance at Technical Support for assistance at 919-762-1000 option 2.
  • Page 31 If wire breaks or loose attempt to ignite oven. attempt to ignite oven. connections are not found, call Southbend Technical Service. Replace ignition module Replace ignition module and attempt to ignite oven. and attempt to ignite oven.
  • Page 32 ROUBLESHOOTING ADIANT ROILER TROUBLESHOOTING CONVECTION-OVEN BLOWER WARNING Before attempting to service or replace any electrical component, make sure power source has been disconnected. CAUTION When changing motor or servicing oven, always verify that blower wheel rotation is clockwise when looking into the oven cavity.
  • Page 33 ADIANT ROILER ROUBLESHOOTING Figure 15 Convection-Oven Blower Does Not Run Convection-oven blower does not run. DISCONNECT POWER AT CIRCUIT BREAKER. Remove the control knobs from the front of the range. Remove the screws that secure the top of the control panel and carefully tilt the panel forward to expose the back of the blower switch that is mounted in the front panel.
  • Page 34 ROUBLESHOOTING ADIANT ROILER Figure 16 Convection-Oven Blower Does Not Run, Continued (Continuing from previous page.) CHECK THAT POWER IS DISCONNECTED AT CIRCUIT BREAKER. Remove the wire terminal cover from the blower motor. Check that the red wire is capped off. Remove the wire nuts from the black and the white wires.
  • Page 35 ADIANT ROILER ROUBLESHOOTING Figure 17 Wiring Diagram for 120 Volt Oven Bases with Electronic Ignition OWNER’S MANUAL 1199797 REV 0 (6/14) PAGE 35 OF 40...
  • Page 36 ROUBLESHOOTING ADIANT ROILER Figure 18 Wiring Diagram for Oven Base with Standing Pilot PAGE 36 OF 40 OWNER’S MANUAL 1199797 REV 0 (6/14)
  • Page 37 ADIANT ROILER ROUBLESHOOTING Figure 19 Wiring Diagram 240V Oven Base with Electronic Ignition OWNER’S MANUAL 1199797 REV 0 (6/14) PAGE 37 OF 40...
  • Page 38 ROUBLESHOOTING ADIANT ROILER Notes: PAGE 38 OF 40 OWNER’S MANUAL 1199797 REV 0 (6/14)
  • Page 39 ADIANT ROILER ROUBLESHOOTING Notes: OWNER’S MANUAL 1199797 REV 0 (6/14) PAGE 39 OF 40...
  • Page 40 ROILER RADIANT BROILERS A product with the Southbend name incorporates the best in durability and low maintenance. We all recognize, however, that replacement parts and occasional professional service may be necessary to extend the useful life of this appliance. When service is needed, contact a Southbend Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number, serial number, and type of your appliance.

This manual is also suitable for:

P32d-3240P32c32bP32a3240