Top Convection Deflector

Install the top convection deflector as shown to the
right.
The deflector is shipped on top of the insert. The
screws are shipped inside the owner's pack.

Fireplace Requirements

Insert must be placed within a code-conforming masonry fireplace. Repair any fireplace damage
prior to installation.
Because the insert uses a circulation blower, clean the fireplace, smoke shelf, and chimney prior to
installation.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.
Min. 603mm
The gas line and shutoff
valve should be installed
prior to insert placement.
© Travis Industries
For tight fits (under 711mm), you may remove the manifold. See the section
"Removing the Manifold"
Min. 800mm - additional space may be required for gas line installation
4040808
Attach the "This fireplace has been altered..." plate
to the fireplace (use two screws or other suitable
method). You may wish to place it in a location
where it will be covered by the surround panels.
The DVL inserts 368mm into the
fireplace.
See "Leveling Bolts" for details
on leveling the heater.