38
Optional Equipment
5
Install the logs and
embers.
6
Replace glass and
face.
7
Remove the
regulator from the
front of the gas
control valve.
Replace with the
LPG regulator,
using the new
gasket and screws
included with the
regulator. NOTE:
Leak test this
area after the
heater is
installed, gas is
connected, and
the main burner
is lit.
8
Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.
WARNING:
When lighting or re-lighting the pilot, the glass must be removed (see page 20).
To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
© Travis Industries
(for authorized personnel only)
a
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
c
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
Slotted
Screwdriver
(or T-20 Torx)
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
Standard
Screwdriver
4040808
b
Remove and discard the
regulator, diaphram, spring
and center post.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
d
Place the LP
label on the base
near the gas
control valve.
100-01201_000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvl insert ef ii

Table of Contents