WARNING:
If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
-
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
-
Inst allat ion and service must be performed by a qualified inst aller, service agency or t he gas
supplier.
This appliance may be installed as an OEM installation in a manufactured (mobile) home and
must be installed in accordance with the manufacturer's instructions and the manufactured home
construction and safety standard, Title 24 CFR, Part 3280.
This appliance is only for use with the type(s) of gas indicated on the rating plate. A
conversion kit is supplied with the appliance.
Installer:
After installation give this manual to the home-owner
and explain operation of this heater.
 Copyright 2007, Travis Industries, Inc.
DVL EF Fireplace
Owner's Manual
OMNI-Test Laboratories, Inc.
• Built-In Direct Vent Fireplace
• Natural Gas or Propane
• Residential or Mobile Home
$10.00
100-01147
Featuring the
Burner
Tested and Listed by
Beaverton, Oregon
Report # 028-S-23B-5
ANSI Z21.88
Travis Industries, Inc.
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DVL EF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Travis Industries DVL EF

  • Page 1 Installer: After installation give this manual to the home-owner Travis Industries, Inc. and explain operation of this heater. 4800 Harbour Pointe Blvd. SW Mukilteo, WA 98275  Copyright 2007, Travis Industries, Inc. $10.00 100-01147...
  • Page 2: Introduction & Important Information

    Introduction Introduction We welcome you as a new owner of a Travis Industries gas fireplace. In purchasing this fireplace you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Travis Industries DVL EF Fireplace is one of the finest home heaters the world over.
  • Page 3: Table Of Contents

    Horizontal Terminations w/ 1 Vertical Elbow ..23 Index............46 Horizontal Terminations w/ 3 Vertical Elbows.24 Vent Termination Requirements ......25 Gas Line Requirements .........26 Fuel ............26 Gas Line Connection........26 Gas Inlet Pressure ........26 Electrical Connection........27 Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 4: Safety Precautions

    Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 5 Always follow the instructions in this manual. • If the fiber logs become damaged, replace with Travis Industries log set. • Children and adults should • Travis Industries, Inc. be alerted to the hazards of grants no warranty,...
  • Page 6: Features & Specifications

    43-7/8"* 2-5/8" 20-1/4"* 6-5/8" WARNING: A 1" clearance from the fireplace enclosure is required along the sides and back of the fireplace. * Includes the 1" clearance (stand-offs) Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 7: Installation

    See the section thermostat wire (on both sides) "Hearth Requirements" See the section "Fireplace See the section See the section "Minimum Placement Requirements" "Gas Line Installation" Framing Dimensions" Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 8: Fireplace Placement Requirements

    Due to the high temperature of the fireplace, it should be located out of traffic and away from furniture and draperies. • Fireplace must be placed so the vents below and above the glass do not become blocked Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 9: Corner Installations

    The fireplace may not be raised so as to place the ceiling within 36" of the base of the fireplace. Raised fireplace with Raised fireplace raised hearth. Raised Platform Raised Hearth Hearth Raised Nail the nail down plates to the floor Platform (or raised platform) Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 10: Hearth Requirements

    Make sure to accomodate the floor covering (carpet, linoleum, Fireplace Stand flooring, etc.) when determining the height of the fireplace stand (i.e. the thicker the carpet, the taller the fireplace stand). Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 11: Facing Requirements

    FPX Arts & Crafts with shield 12" 12" 12" FPX French Country 15.5" 15.5" 15.5" FPX French Country with shield 12" 12" 12" Lopi Discovery 13" 13" 13" Lopi Wilmington 17” 17” 17” Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 12: Facing Over 1" Thick

    Arch Faces 1” above the base of the fireplace. 34 Arch Set-Up Face is available from Use the optional Arch Set-Up Face Travis Industries (Part # 98500694) available from Travis Industries. 1” • Artisan faces vary in size. Use the face being installed to create a template.
  • Page 13: Face Dimensions

    32-3/4” Classic Arched, Artisan 26-1/2” 34-3/4” Side begins arch 3-1/2” below top - 45” radius Metropolitan 26-1/2” 34-3/4” Architectural Series 27-7/8” 33-5/8” Discovery 26’ 35-3/4’ Wilmington 27” 36-1/8” Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 14: Modifying The Face Angle

    Screwdriver angle. Front of Fireplace Glass Re-bend the face angle at the Straighten the face angle. inward location and re-attach the lower portion with one screw. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 15: Facing & Hearth Examples

    Note how the tile facing fits behind the face on the side and top and butts up to the face on the bottom. 2x4 and Plywood Platform Tile Cement Board Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 16: Side View

    Wood Sub Floor 1/2" Cement Board 3/8" Tile Do not install cement board underneath the fireplace. To do so WARNING: would leave a large gap underneath the finish faceplate sides. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 17: Mantel Requirements

    FPX Arts & Crafts with shield 15" 15" 15" FPX French Country 16" 18" 19" FPX French Country with shield 15" 15" 15" Lopi Discovery 16" 16" 16" Lopi Wilmington 19” 19” 19” Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 18: Vent Requirements

    1245B 45° Elbow, Black 1290B 90° Elbow, Black Firestops & Support 93006094 Travis Hor. Firestop (44 DV XXL or DVL FP EF) 1263 Ceiling Firestop 1288 Wall Strap Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 19: Vent Installation

    If it does not, apply high temperature sealant to the joints of the affected sections. • Horizontal sections require a 1/4" rise every 12" of travel • Horizontal sections require non-combustible support every three feet (e.g.: plumbing tape) Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 20: Approved Vent Configurations

    NOTE: 3-3/8" of overlap Vent sections overlap each other by 1-3/4" 1-3/4" Vent Length Vent (2', 3', etc.) 42" Height NOTE: All measurements are for 8" diameter vent. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 21: Vertical Terminations (With/ Without Offsets)

    15 feet 10 feet 10 feet 10 feet 10 feet (min.) (min.) 5 feet 5 feet 5 feet 5 feet 0 feet 0 feet 0 feet 0 feet Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 22: Vertical Terminations With 2 90° Elbows

    Horizontal length is calculated by adding each 5 feet 5 feet horizontal run together. NOTE: Horizontal sections require a 1/4" rise every 12" of travel. 0 feet 0 feet Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 23: Horizontal Terminations W/ 1 Vertical Elbow

    Restrictor Position #5 15 feet 15 feet Restrictor Position #4 10 feet 10 feet Restrictor Position #2 Restrictor Position #1 5 feet 5 feet 0 feet 0 feet Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 24: Horizontal Terminations W/ 3 Vertical Elbows.24

    Restrictor 15 feet 15 feet Position #5 Restrictor Position #4 10 feet 10 feet Restrictor Position #2 Restrictor Position #1 5 feet 5 feet 0 feet 0 feet Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 25: Vent Termination Requirements

    Use the vinyl siding standoff when installing on an exterior with vinyl siding. • Vent termination must not be located where it will become plugged by snow or other material • These clearances meet UMC-1994 code standards. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 26: Gas Line Requirements

    The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the regulator is at an improper pressure. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 27: Electrical Connection

    Attach the common (white), ground (exposed or green) wires, and hot (black) wires from the power source to the electrical connector (attached to the fireplace). Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 28: Finalizing The Installation

    Hang the glass frame on the firebox. While holding in place, attach the upper latches (follow the instructions to the right in reverse). Lift the glass frame slightly and attach the lower latches. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 29 Insert the spring pin into this bracket with the pins aligned vertically. Push in slightly and twist 1/4 turn. With this pin horizontal, the spring pin will remain in place. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 30: Log & Coal Installation

    Place the embers over the front and side edges of the burner (do not place them over the burner holes). Place them in a random pattern. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 31: Purge Gas Line And Replace The Glass

    If the flames are too tall or sooty on the If the flames are all blue and base, yellow-orange on the top. ends, open the air shutter. short, close the air shutter. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 32: Check Flame

    Give this manual to the home owner and fully explain the operation of this heater. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 33: Operation

    Flame Adjust Knob This knob controls the flame height from low ("LO") to high ("HI"). The pointer above the knob points to the position this knob is in. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 34: Starting The Pilot

    “f”. Replace the glass. Turn the gas control knob counter-clockwise to "ON". The pilot is now lit and the heater can be turned on and off. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 35: Starting The Fireplace For The First Time

    Your fireplace has an adjustable flame to tailor the look and heat output to your specific needs. It is adjusted by turning the middle dial on the gas control valve. Index Mark Flame Height Adjustment Knob Turn counter-clockwise to adjust the flame higher, clockwise to lower. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 36: Adjusting The Blower Speed

    This is normal during start-up. You may notice the smell is more acute if the appliance was left idle for a long period. Travis Industries 1 0 0 - 0 1 1 4 7...
  • Page 37: Maintenance

    If the pilot or main burners do not burn correctly, contact your dealer for service. Monitor the blower operation. Remove any debris or vegetation near the vent termination. Contact your dealer if any sooting or deterioration is found near the vent termination. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 38: Troubleshooting Table

    Thin Layer of Soot The logs or coals are placed incorrectly See "Log Set Installation and Removal" Covers the Glass Improper air shutter adjustment Adjust Air Shutter - contact your dealer Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 39: How This Fireplace Works

    It has been amount of electricity. If the pilot flame tested to be extremely resistant to goes out, the gas valve automatically breakage from temperature changes. shuts off all gas. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 40: Wiring Diagram

    Replacement Parts List Caution: Use only Travis Industries replacement parts. Do not use substitute materials. Warning: Do not operate appliance with the glass front removed, cracked, or broken. Replacement of the glass should be done by a licensed or qualified service person.
  • Page 41: Safety Label

    Safety Label The safety (listing) label is on a plate chained to the gas control valve. A copy of the safety label is shown to the right. Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 42: Warranty

    At that time, you may be asked to ship your appliance, freight charges prepaid, to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC., at its option, will repair or replace, free of charge, your TRAVIS appliance if it is found to be defective in material or workmanship within the time frame stated within this 7 year warranty.
  • Page 43: Optional Equipment

    1/2" Wrench install. The NG orifices have “45” stamped on them. 5/16” NOTE: Screw the LP orifice in so the orifice shoulder protrudes 5/16” (indicating full insertion). Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 44 Clockwise thermopile (see the illustration below). Adjust the pilot up or lowers the flame while counter-clockwise raises it. Standard down as necessary. Screwdriver Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 45 Optional Equipment (for qualified installers only) Travis Industries 1 0 0 - 0 1 1 4 7 4041206...
  • Page 46: Index

    What Turns the Main Burners On and Off....39 Glass, Glass Gasket...........28 Wiring Diagram..........40 Hearth Requirements........10 Yearly Service Procedure........37 Heating Specifications ........6 Horizontal Vent Termination Requirements ..25 How this Fireplace Works........39 Travis Industries 1 0 0 - 0 1 1 4 7 4041206...