FINE TUNING THE EMBER-FYRE™ BURNER
Each installation is affected by altitude, vent configuration, and fuel quality. Because of this, the restrictor and
air shutter may need to be fine tuned to each installation. Follow the hints below to fine-tune the burner for
optimum performance and aesthetics.
Air Shutter Hints:
For more glow, open the air shutter, however, this will make the flames more blue.
For yellow flames, close the air shutter, however, this may create less glow.
Correct Flames
The flames should burn right
off the top of the burner ports
(if they are too blue, adjust
the air control).
Warning:
If the vent configuration is installed incorrectly the vent may cause the flames inside the heater to lift or
"ghost" – a dangerous situation. Inspect the flames after installation to insure proper performance. If
the vent configuration is correct, yet the flames are lifting or ghosting, shut off gas to the heater and
contact the dealer for information on remedying the problem.
8. Replace the glass.
9. Attach the face following the directions included with the face.
NOTE: If using the Classic Arched, Artisan, Metropolitan or
Victorian Lace Face you must use the face mounting
brackets included with the heater (SKU 225-20054). See
page 11 for details.
10. Turn the flame adjust knob to its highest position - the flames
should not contact the top of the firebox. Check the flame on
low position. The flames should burn off of each burner hole.
If the heater does not work correctly, contact your dealer for a
remedy.
11. Give this manual to the home owner and fully explain the operation of this heater.
© Travis Industries
Finalizing the Installation
Lifting Flames
Burner Ports
Burner
Lifting flames indicate
insufficient draft (restrictor
is set too high).
Ghosting Flames
(holes)
Ghosting flames indicate
insufficient air (restrictor set too
high, air shutter shut down, or
other venting error).
New Brackets
4040808
Flickering Flames
Flickering, short flames
indicate excessive draft
(move air shutter to a higher
position).
Old Brackets
100-01201_000