Top Convection Deflector; Fireplace Requirements - Travis Industries DVS GSR2 NB Owner's Manual

Direct vent fireplace insert
Hide thumbs Also See for DVS GSR2 NB:
Table of Contents

Advertisement

Installation (for qualified installers only)

Top Convection Deflector

Install the top convection deflector as
shown to the right.
The deflector is shipped on top of the
insert. The screws are shipped inside
the owner's pack.

Fireplace Requirements

Insert must be placed within a code-conforming masonry fireplace or tested and listed factory-
built (metal) wood-burning fireplace. Repair any fireplace damage prior to installation.
Because the insert uses a circulation blower, clean the fireplace, smoke shelf, and chimney prior
to installation.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this
appliance produces when determining a location.
f
a
e
h
Attach the "This fireplace has been altered..." plate to the fireplace (use two screws or other
suitable method). You may wish to place it in a location where it will be covered by the surround
panels.
© Travis Industries
b
g
c
d
Fireplace Sizing
a
Minimum Height
b
Minimum Width
c
Minimum Depth
d
Hearth Extension
h
The gas and electrical line should be installed prior to
e
installing the heater.
For tight fits (under 24" 610mm) see the section
f
"Removing the Vent Connector"
g
See "Leveling Bolts" for details on leveling the heater.
4131108
3-Piece Panel
1-Piece Panel
19-1/2" (496mm)
20-5/8" (524mm)
26-1/2" (674mm)
29" (737mm)
15-1/8" (385mm)
16-3/8" (416mm)
1-1/4" (32mm)
0" (0mm)
100-01317
9