Display messages
5.2
Messages for troubleshooting
Brewer
place brewer
brewer pos. switch
Flow
clear fl ow stopped
(Water tank is empty)
The brewing unit is not inserted.
>
Insert the brewing unit.
The brewing unit is not inserted.
>
Check if the brewing unit is inserted correctly.
The brewing unit is inserted only with diffi culty or not at
all inserted:
>
Remove the brewer.
>
Open the brewing chamber with the multitool.
>
Apply a thin layer of grease from the accessories to the
red gaskets (chapter "4.4.2 Lubricating O-Ring of the
Water tank" on page 76).
>
Fill the water tank.
>
Deaerate coffee machine: Dispense hot water until a
constant stream of water comes out.
80